The Rack LCD Console with Integrated KVM Switch combines the functionality of Rack LCD Console and Analog KVM switches in one convenient package optimizing U space in the rack environment, eliminating cable clutter, and offering a value of two products functionality in one package.Out-of-band managementScalable ArchitectureOccupies 1U of rack spaceMulti-platform SupportIntegrated Touchpad Pointing DevicePower tilt sensorPS/2 terminationsStandard VGA connectorLow Cooling requirementsLow Power Consumption
The new 128MB BBWC Enabler is a transportable 128MB battery module increasing the total memory of the controller to 192MB for RAID, read cache, and BBWC. The transportability of the battery memory module protects the write cache data from unexpected power loss, system board failure, or controller board failure. Data retained in the write cache will be protected for up to 72 hours, allowing time to restore power, or transport the module to a functioning system board or array controller. The modular design of the battery memory module is transportable between the Smart Array 641 and Smart Array 642 controllers.
M6 hardware for mounting equipment in enclosure with square hole mounting rails. Qty. 32 sets of M6 cage nuts, nylon washers and slot/phillips screws.M6 hardware for mounting equipment in enclosure with square hole mounting railsQty. 32 sets of M6 cage nuts, nylon washers and slot/phillips screws.
Installs in various locations within the enclosure, for example, on the vertical mounting flanges and on the vertical 0U accessory channels. Provides mounting options for Rack PDUs and other small accessories.Installs in various locations within the enclosurefor example, on the vertical mounting flanges and on the vertical 0U accessory channelsProvides mounting options for Rack PDUs and other small accessories.
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.Remote Management CapabilitiesLocal Current Monitoring DisplayAlarm ThresholdsLoad indicator LEDIntegrates with InfraStruXure CentralFlash UpgradeableRack-MountableSingle input power sourceWide range of input and output connections
Original part number PN101G Product name LOGILINK- 19'' Solid Blank Panel 1U, grey Producer LogiLink Class of product Component for rack 19"&10" Component for rack 19 Blank panel Additional information Blanking cover for 19" rack-mountingDimension: 1U, 482,6x44,45mmMaterial: 1.2 mm steelFinish: Electrostatic powder paintColor: RAL 7035 light grey Net weight 300 g Datasheet Data sheet
Original part number AC111 Product name LOGILINK- Mounting Set M6, 20pcs Producer LogiLink Class of product Component for rack 19"&10" Component for rack 19 Mounting kit Additional information Mounting set for fixing 19" device into a cabinetMaterial: Zinc plated Steel, plasticContent: Screw, plastic washer, cage nutDiameter: 6 mm (M6)Set of 20 Net weight 200 g Datasheet Data sheet