Vertical cable organizer for standing cabinets, 2 pieces, black A set of 2 pieces of black vertical cable organizers 22U intended for installation in Lanberg FF01 and FF02 series 19" floor-standing cabinets, 800 mm wide and 22U high.
LogiLink’s high quality Cat.6 flat and slim patch cords are ideal for installation in data-centers and other places with limited space. This high flexible patch cable provides also plenty of ventilation space for network rack components, while improving the look of your wiring setup when installed in plain view. It is ideal for network adapters, hubs, switches, and patch panels where space or cable flexibility is an issue.
See Delocki USB-kaabel võimaldab USB 3.0 ühenduse pikendamist ja on varustatud väärika metallkorpusega ning kullatud pistikutega. Märkus Aktiivsete USB-seadmete, nt väliste kõvakettakappide kasutamiseks on vaja ühendatud seadme jaoks täiendavat toiteallikat. Spetsifikatsioon - Ühendused: 1 x USB 3.0 Type-A isane > 1 x USB 3.0 Type-A emane - Kaabli gabariit: 28 AWG andmeliin 24 AWG toiteliin - Paindumiskaitse liitekohal - Kaabli läbimõõt: ca 5,5 mm - Vaskjuht - Kontaktid kullatud - Ühendused kullatud punase metallkorpusega - Kaabel topeltvarjestatud - Andmeedastuskiirus kuni: SuperSpeed 5 Gbps, Hi-Speed 480 Mbit/s, Full-Speed 12 Mbit/s, Madala kiirusega 1,5 Mbit/s - Värv: Kaabel: must pistikud: punane - Pikkus koos pistikutega: ca. 1 m Süsteeminõuded - Arvuti või sülearvuti, millel on vaba USB A-tüüpi port Pakendi sisu - USB 3.0 pikenduskaabel
CAT 5e patchcable, F/UTP, grey CCA material mixture shielded LAN/network cable to connect network components with 2 x RJ45 connectors outer shield: foil screening with 3µ gold plated PINs with length indication on the slimline strain relief with latch protection pair-sequence acc. to EIA/TIA 568B suitable for Gigabit (10/100/1000 Mbit) network Technical specifications Connections Connection, type RJ45 male (8P8C) Connection 2, type RJ45 male (8P8C) Connection, shielding yes Latch protection both sides Cable Cable type round cable Specification CAT 5e Shielding class F/UTP AWG 26/7 (stranded) Cable sheath diameter (approx.) 5.5 mm Inner conductor material CCA (copper-clad aluminium) Cable length 7.5 m Material cable sheath PVC Number of shieldings 1 x Type 1, shielding foil (aluminium) Kink protection both sides Signal transmission max. bandwidth 100 MHz General Consumption Unit 1 pc. in polybag Color grey Markings CE, WEEE
Cat.6 U/UTP PVC network cable with support for bandwidth up to 250 MHz and features a snagless design with gold plated contacts for Ethernet standards up to 1GBase-T. Cat.6 cable for operating frequencies up to 250 MHz. The unshielded version (U/UTP) can be used for Gigabit Ethernet thanks to the special design of the electrophysical parameters (NExT, FExT, etc.) despite the lack of shielding. These cables are manufactured and tested according to the ISO/IEC 11801 specification. The cables are packaged individually in a polybag. The gold-plated contacts ensure reliable, corrosion-free connections over extensive periods of time. A robust snagless strain relief design prevents damage to the connector latch during installation and removal.
Cat 7 S/FTP LSZH network cable with Cat 6a connectors supports bandwidth up to 600 MHz and features a snagless design with gold-plated contacts for Ethernet standards up to 10 GBase-T.The Cat 7 cable material for operating frequencies up to 600 MHz with braided shielding and foil single-wire shielding (S/FTP) was developed for use in data centers, server rooms, rack mounting of network and control cabinets etc. for networks of 10 GBase-T.The gold-plated contacts ensure reliable, corrosion-free connections over extensive periods of time. A robust snagless strain relief design prevents damage to the connector latch during installation and removal.This product uses Cat 7 cable material. The Cat 7 standard originally defined the GG45 connectors, which were intended as a further development of RJ-45, but were not able to establish themselves on the market. In the meantime, the RJ-45 connector developed to easily meet the requirements of Cat 7, but has never been defined for Cat 7. Therefore the imprint on the cable reads as follows: "Cat 6a S/FTP patch cords with 600 MHz raw cable".