The 1000Base-EX Industrial SFP Single-Mode LC Module, model TI-MGBS40, is designed to operate within a wide temperature range and is well suited for industrial environments. This SFP module works with standard SFP slots found on industrial switches and fiber converters. The TI-MGBS40 is compatible with duplex LC fiber connector types and supports gigabit single-mode fiber connections at distances of up to 40 kilometers (24.8 miles). Fiber Applications Long distance fiber networking for industrial, manufacturing, and corporate / education campus applications. Fiber Mode / Distance Single-Mode transceiver spans distances up to 40 km (24.8 miles) and supports up to 1.25Gbps. Compatibility Hot-pluggable with a MSA compliant SFP slot and compatible with fiber cables with LC-type duplex connectors. Hot-Pluggable SFP Hot-pluggable SFP transceiver compatible with a MSA compliant SFP slot Fiber Wavelength Compatible with single-mode 1310nm transmissions Fiber Distance Supports networking for distances up to 40km (24.8 miles) Fiber Interface LC-type duplex connector Operating Temperature Rated for an operating temperature range of -40°– 85 °C (-40° – 185 °F)
8 x Gigabit UPoE porti 8 x Gigabit PoE+ porti 4 x jagatud Gigabit-porti (RJ-45 või SFP) Toetab PoE (15,4 W), PoE+ (30 W) ja UPoE (60 W) toiteallikaid 370W PoE võimsuse eelarve Lihtne veebipõhine haldusliides Toetab IPv6, LACP, VLAN-i, QoS-i ja IGMP Snoopingi Ribalaiuse juhtimine pordi kohta Era- ja Voice VLANi tugi Nutikas ventilaator 40 Gbps kommutatsioonivõimsus IEEE 802.1p QoS koos järjekordade ajastamise toetusega TRENDneti 20-portiline Gigabit Web Smart UPoE Switch, mudel TPE-204US, pakub täiustatud haldusfunktsioone koos 40 Gbps lülitusvõimsusega. See rack-paigaldatav IPv6-valmis kommutaator on varustatud intuitiivse veebipõhise kasutajaliidesega. Täiustatud liiklusjuhtimise kontroll koos SNMP-seirega teeb sellest võimsa lahenduse VKE-võrkudele. TPE-204US pakub kaheksa gigabitist UPoE-porti ja kaheksa gigabitist PoE+-porti, mille koguvõimsus on 370 W, ning neli jagatud gigabitist porti (RJ-45 või SFP). UPoE-standard annab kuni 60 W võimsust ühe pordi kohta selliste seadmete jaoks nagu suure võimsusega traadita juurdepääsupunktid, PTZ (Pan Tilt Zoom) IP-kaamerad ja VoIP-telefonisüsteemid. Nutikas veebihaldus Pakub hõlpsasti kasutatavat veebipõhist haldusliidest, mis vähendab lülitite konfigureerimise keerukust ja pakub lihtsaks kasutuselevõtuks kombineeritud SMB-haldusfunktsioone. Integreerimise paindlikkus Haldusfunktsioonide hulka kuuluvad juurdepääsukontrolli nimekirjad, VLAN, IGMP snooping, QoS, RMON, SNMP trap ja syslog jälgimiseks ja paindlikuks võrguintegratsiooniks. UPoE võimsus 370 W PoE-võimsuse eelarve varustab PoE/PoE+/UPoE-seadmeid toiteallikaga. Riistvara disain Omab 8 gigabit UPoE-porti, 8 gigabit PoE+-porti, 4 jagatud gigabit-porti (RJ-45 või SFP) ja 1U rackmount-konstruktsiooni (klambrid kaasas). PoE toide Varustab PoE-seadet PoE (15,4 W), PoE+ (30 W) või UPoE (60 W) toiteallikaga ning PoE-võimsuse kogueelarve on 370 W. IPv6-valmis See kommutaator toetab IPv6-aadressi konfigureerimist ja IPv6 naabrite avastamist. Liikluse juhtimine Lai valik võrgukonfiguratsioone on toetatud: 802.3ad linkide koondamine, asümmeetriline VLAN, 802.1Q VLAN, Voice VLAN, RSTP, MSTP, Loopback Detection, GVRP, 802.1p teenuseklass (CoS), portide ribalaiuse haldamine ja QoS järjekordade ajastamine. Veaotsing Mugav kaabli diagnostikatest ja liiklusstatistika aitab võrgu tõrkeotsingul. Juurdepääsu kontroll Omadused juurdepääsukontrollile, nagu ACL, SSL, MAC/portide filtreerimine, 802.1X, TACACS+ ja RADIUS. Seire RMON, SNMP, SNMP Trap ja portide peegeldamise tugi.
QuMax Teltonika RUTX10 jaoksIntegreeritud Wi-Fi kahesageduslik 2,4 ja 5 GHz sektori antenn + Bluetooth sektori antenn + koht Teltonika RUTX10 paigaldamiseks (All-in-one). QuMAX pakub QuWirelessi antennidest kõige võimsamat Wi-Fi dual band 2,4 & 5 GHz sektoriantenni. See on mõeldud suure levialaga hotspotidele ja püsivõrkude tugijaamadele. See on mõeldud Teltonika RUTX10 ruuteri paigaldamiseks IP67 korpusesse. See on esimene valik tööstuskeskkonna püsipaigaldiste jaoks. Sellesse on sisseehitatud ka Bluetooth sektori antenn.Kõik antennid ja Teltonika ruuter on integreeritud ühte korpusesse.Välitingimustes kasutatav antenn töötab igas ilmastikutingimustes, IP67.Antenni on ruuteriga ideaalselt sobitatudPassiivne PoE tugiTranslated with DeepL.com (free version)
QuSpot for Teltonika RUTX10 Integrated outdoor Wi-Fi dual band 2.4 & 5 GHz omni antenna + Bluetooth omni antenna + place to install Teltonika RUTX10 (All-in-one) QuSpot Wi-Fi antenna for Teltonika RUTX10 router is a perfect outdoor device for mobile and fixed installations like industrial, CCTV, hotspots, yachts, boats, campers, RV etc. It has embedded also Wi-Fi dual band 2.4 & 5GHz omni antenna and Bluetooth omni antenna. If you use RUTX10 with QuSpot antenna, you get an integrated complete solution with embedded router and multi band antennas in one enclosure. All antennas and Teltonika router integrated in one enclosure Outdoor antenna works in any weather conditions, IP67 Antenna perfectly matched with the router Passive PoE support
CAT8 SSTP Patch CableVention CAT8 cables are capable of reaching up to 40Gbps transfer speeds and up to 2000MHz bandwidth. These CAT8 patch cords consist of 4 pairs 28 AWG stranded copper conductors and RJ45 connectors. Cat.8 patch cables are backwards compatible with CAT5E CAT6 CAT6A and CAT7.Used to connect your network device to any of the following: 40GBASE-T Gigabit Ethernet 25GBASE-T Gigabit Ethernet 10GBASE-T Gigabit Ethernet 1000BASE-T Gigabit Ethernet 100BASE-TX Fast Ethernet 10BASE-T Ethernet CAT8 Performance for a 10GBASE-T 25GBASE-T or a 40GBASE-T channel compliant network up to 30 meters; 10Gbps support up to 100 meters. Optimize the distance and power in high density networking End of Row (EOR) Top of Rack (TOR) or Middle of Row (MOR) configurations at the data center. Cat 8 supports interconnect topologies that are limited to 2 connections in a 30 meter channel for 25Gbps or 40Gbps network speeds.Vention CAT8 patch cord provides a lower cost alternative than OM3 fiber connections under 30 meters or a SFP+ twin-axial connection under 5 meters; Cat 8 Ethernet cable supports auto-negotiation for compatibility with mixed network server speeds from 1 Gbps to 40 Gbps.The superior Shielded design of this Cat 8 cable includes individually foil-shielded bare copper connectors encased in a overall steel braid; fully shielded metal connectors have gold-plated RJ45 contacts and a snag-less boot with molded strain relief; Tested to support up to 2000 MHz (2 Ghz) that is 4x the frequency of Cat 6A cable or Cat7 cable.
Environmentally Hardened Design PLANET Industrial 8-port Gigabit 802.3at PoE+ Switch, IGS-5225-8P2T2S, is equipped with a rugged IP30 metal case for stable operation in heavy industrial demanding environments. Thus, the IGS-5225-8P2T2S provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Being able to operate under wide temperature range from -40 to 75 degrees C, the IGS-5225-8P2T2S can be placed in almost any difficult environment. The IGS-5225-8P2T2S also allows either DIN rail or wall mounting for efficient use of cabinet space. Redundant Ring, Fast Recovery for Critical Network Applications The IGS-5225-8P2T2S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple Ring network, the recovery time of data link can be as fast as 20ms. High Power PoE for Security and Public Service Applications To fulfill the demand of High Power PoE for network applications with Gigabit speed transmission under wide temperature, the IGS-5225-8P2T2S provides 8 10/100/1000Mbps ports featuring IEEE 802.3at Power over Ethernet Plus (PoE+) that combines up to 36-watt power output and data per port over one Cat5E/6 Ethernet cable. As the whole system comes with a total 240-watt PoE budget, the IGS-5225-8P2T2S is designed specifically to satisfy the growing demand of higher power consuming network PDs (powered devices) such as multi-channel (802.11a/b/g/n) wireless LAN access points, PTZ (Pan, Tilt & Zoom)/Speed Dome network cameras and other PoE network devices, doubling that of the current conventional 802.3af PoE. Convenient and Smart ONVIF Devices with Detection Feature PLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for co-operating with video IP surveillances. From the IGS-5225-8P2T2S’ GUI, you just need one click to search and show all of the ONVIF devices via network application. In addition, you can upload floor images to the switch and can remotely monitor or inspect an assembly line. Moreover, you can get real-time surveillance information and online/offline status; the PoE reboot can be controlled from the GUI. Intelligent Alive Check for Powered Device The IGS-5225-8P2T2S PoE Switch can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-5225-8P2T2S will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden. PoE Schedule for Energy Saving Under the trend of energy saving worldwide and contributing to environmental protection on the Earth, the IGS-5225-8P2T2S can effectively control the power supply besides its capability of giving high watts power. The built-in “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money. Scheduled Power Recycling The IGS-5225-8P2T2S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow. SMTP/SNMP Trap Event Alert The IGS-5225-8P2T2S provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response. Effective Alarm Alert for Better Protection The IGS-5225-8P2T2S supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. Digital Input and Digital Output for External Alarm The IGS-5225-8P2T2S supports Digital Input and Digital Output on its upper panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-5225-8P2T2S port shows link down, link up or power failure. Layer 3 IPv4 and IPv6 Software VLAN Routing for Secure and Flexible Management To help customers stay on top of their businesses, the IGS-5225-8P2T2S not only provides ultra high transmission performance and excellent Layer 2 technologies, but also IPv4/IPv6 software VLAN routing feature which allows to crossover different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application. Robust Layer 2 Features The IGS-5225-8P2T2S can be programmed for advanced switch management functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Rapid Spanning Tree Protocol, Layer 2 to Layer 4 QoS, bandwidth control and IGMP snooping. The IGS-5225-8P2T2S provides 802.1Q tagged VLAN, and the VLAN groups allowed will be maximally up to 255. Via aggregation of supporting ports, the IGS-5225-8P2T2S allows the operation of a high-speed trunk combining multiple ports. It enables a maximum of up to 6 trunk groups with 4 ports per trunk group, and supports fail-over as well. Efficient Management For efficient management, the IGS-5225-8P2T2S is equipped with console, Web and SNMP management interfaces. With the built-in Web-based management interface, the IGS-5225-8P2T2S offers an easy-to-use, platform-independent management and configuration facility. For text-based management, the IGS-5225-8P2T2S can be accessed via Telnet and the console port. Moreover, it also offers secure remote management via any standard-based management software by supporting SNMPv3 connection which encrypts the packet content at each session. Powerful Security The IGS-5225-8P2T2S offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1x Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before. Modbus TCP provides Flexible Network Connectivity for Factory Automation With the supported Modbus TCP/IP protocol, the IGS-5225-8P2T2S can easily integrate with SCADA systems, HMI systems and other data acquisition systems in factory floors. It enable administrators to remotely monitor the industrial Ethernet switch’s operating information, port information and communication status, thus easily achieving enhanced monitoring and maintenance of the entire factory. Flexibility and Extension Solution The additional four mini-GBIC slots built in the IGS-5225-8P2T2S support dual speed, 100BASE-FX and 1000BASE-SX/LX SFP (Small Form-factor Pluggable) fiber-optic modules, meaning the administrator now can flexibly choose the suitable SFP transceiver according to not only the transmission distance but also the transmission speed required. The distance can be extended from 550 meters (multi-mode fiber) to 10/50/70/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions. Intelligent SFP Diagnosis Mechanism The IGS-5225-8P2T2S supports SFP-DDM (Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage. 1588 Time Protocol for Industrial Computing Networks The IGS-5225-8P2T2S is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet. Industrial Area Department/Workgroup PoE Switch Providing up to 8 PoE+, in-line power interfaces, the IGS-5225-8P2T2S can easily build a power centrally controlled for IP phone system, IP camera system, or wireless AP group for Industrial network. For instance, 8 PoE IP cameras or wireless access points can be easily installed around the corner in the industrial environment for surveillance demands or for a wireless roaming network. Without the power-socket limitation, the IGS-5225-8P2T2S makes the installation of IP cameras or wireless AP easier and more efficient.
Robustly Designed for Critical Business Applications Designed to be installed in heavy industrial demanding environments, the IGS-4215-8T2S is the new member of PLANET Industrial-grade, DIN-rail type L2/L4 Managed Gigabit Switch family to improve the availability of critical business applications. It provides IPv6/IPv4 dual stack management and built-in L2/L4 Gigabit switching engine along with 8 10/100/1000BASE-T ports, and 2 extra 100/1000BASE-X SFP fiber ports for data and video uplink. The IGS-4215-8T2S is able to operate reliably, stably and quietly in any hardened environment without affecting its performance. It comes with operating temperature ranging from -40 to 75 degrees C in a rugged IP30 metal housing. Environmentally Hardened Design With the IP30 industrial case, the IGS-4215-8T2S provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets without air conditioner. Being able to operate under the temperature range from -40 to 75 degrees C, the IGS-4215-8T2S can be placed in almost any difficult environment. Robust Protection The IGS-4215-8T2S provides contact discharge of ±6KV DC and air discharge of ±8KV DC for Ethernet ESD protection. It also supports ±4KV surge immunity to improve product stability and protects users’ networks from devastating ESD attacks, making sure the flow of operation does not fluctuate. Redundant Ring, Fast Recovery for Surveillance System The IGS-4215-8T2S supports redundant ring technology and features strong rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In certain simple Ring network, the recovery time of data link can be as fast as < 450ms. Robust Layer 2 Features The IGS-4215-8T2S can be programmed for advanced switch management functions such as dynamic port link aggregation, 802.1Q VLAN, Q-in-Q VLAN, Multiple Spanning Tree Protocol (MSTP), loop and BPDU guard, IGMP snooping, and MLD snooping. Via the link aggregation, the IGS-4215-8T2S allows the operation of a high-speed trunk to combine with multiple ports such as an 8Gbps fat pipe, and supports fail-over as well. Also, the Link Layer Discovery Protocol (LLDP) is the Layer 2 protocol included to help discover basic information about neighboring devices on the local broadcast domain. IPv6/IPv4 Dual Stack Management Supporting both IPv6 and IPv4 protocols, the IGS-4215-8T2S helps the SMBs to step in the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up. Efficient Traffic Control The IGS-4215-8T2S is loaded with robust QoS features and powerful traffic management to enhance services to business-class data, voice, and video solutions. The functionality includes broadcast/multicast/unicast storm control, per port bandwidth control, 802.1p/CoS/IP DSCP QoS priority and remarking. It guarantees the best performance in VoIP and video stream transmission, and empowers the enterprises to take full advantage of the limited network resources. User-friendly and Secure Management For efficient management, the IGS-4215-8T2S is equipped with Command line, Web and SNMP management interfaces. With the built-in Web-based management interface, the IGS-4215-8T2S offers an easy-to-use, platform-independent management and configuration facility. For text-based management, it can be accessed via Telnet and SSHv2 protocol. For standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management. . Powerful Security from Layer 2 to Layer 4 PLANET IGS-4215-8T2S offers comprehensive IPv4/IPv6 Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1X port-based user and device authentication, which can be deployed with RADIUS to ensure the port level security and block illegal users. With the Protected Port function, communication between edge ports can be prevented to guarantee user privacy. Furthermore, Port Security function allows limiting the number of network devices on a given port. Advanced Network Security The IGS-4215-8T2S also provides DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before. Flexibility and Long-distance Extension Solution The two additional SFP slots built in the IGS-4215-8T2S support 100BASE-FX /1000BASE-SX/LX SFP (Small Form-factor Pluggable) fiber transceivers to uplink to backbone switch in long distance. The distance can be extended from 550 meters to 2 kilometers (multi-mode fiber) and up to 120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.   Intelligent SFP Diagnosis Mechanism The IGS-4215-8T2S supports SFP-DDM (Digital Diagnostic Monitor) function that can easily monitor real-time parameters of the SFP for the network administrator, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage. Industrial-grade Switch for Building Automation and Security Suitable for buildings where security is strictly to be enforced, the IGS-4215-8T2S, with eight high-speed Gigabit Ethernet interfaces, can easily build a power centrally controlled for an IP phone system, IP surveillance system, and wireless AP group in the harsh Industrial environment. Model that Withstands Harsh Operation and Extends Distance The IGS-4215-8T2S is made to withstand any harsh operation in such environments as traffic control cabinets, factory floors, and indoor and outdoor locations where temperatures are extremely high or low. With a non-blocking design and compact size, the installation of the IGS-4215-8T2S is easy and helpful to build a Gigabit high-bandwidth switched network quickly.