Cable management accessory to help eliminate cable stress and maintain a neat, organized cable layout within an enclosure or a rack.Facilitates front cable managementIntegrated Front Cable HoopsOccupies 1U of rack space
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.Remote Management CapabilitiesLocal Current Monitoring DisplayAlarm ThresholdsLoad indicator LEDIntegrates with InfraStruXure CentralFlash UpgradeableRack-MountableSingle input power sourceWide range of input and output connections
Toolless, vertical cable management accessory that allows for quick installation and takes up zero U of space within the rack. It helps to eliminate cable stress and organize the cable layout within the rear channels of the NetShelter enclosure.Expanded Cable ManagementFacilitates rear/vertical cable managementOccupies 0U of rack spaceOrganizes data and power cablesTool-less mounting
Product kirjeldus: Schneider Electric Galaxy VS GVSUPS30K0B4HS - UPS - 30 kW - 30000 VA seadme tüüp: UPS - external Bundled Services: Start-Up Service 5X8 kaal: 200 kg Input Wiring: 3-phase sisendpinge: AC 400 V väljundpinge: AC 380/400/415 V ± 3% Power maht: 30 kW / 30000 VA aku: Lead Acid võrguseadeing: Ethernet Remote Management Protocol: SNMP, Modbus Lisatarvikud: Dust filter värv: valge, RAL 9003 mõõtmed (WxDxH): 52.1 cm x 84.7 cm x 148.5 cm Manufacturer Warranty: 1-year garantii
The NetBotz 250 from APC by Schneider Electric is an affordable environmental monitoring appliance for all IT environments. It protects your computing equipment from physical threats such as high temperature, humidity, fluid damage, and both malicious and unintentional access events. With native support for NetBotz wireless sensors, the NetBotz 250 allows for a rapid deployment of your environmental monitoring solution. With its shallow 19" form factor, the NetBotz 250 can be mounted in a rack alongside your other IT gear, or zero-U mounted in the back. The appliance has six on-board ports for connecting various NetBotz wired sensors, including temperature, temp/humidity, smoke, and spot fluid detection sensors, as well as third party sensors via a dry contact cable. Additional dedicated ports include a beacon port, voltage output, relay output, and Modbus connections, for monitoring the device over Modbus RTU or TCP. Thresholds, alerts, and notifications are configured through either the NetBotz 250 web UI or via StruxureWare Data Center Expert. The Data Center Expert integration is especially valuable when you need to manage multiple NetBotz appliances through a single pane of glass. For environments that do not require surveillance, the NetBotz 250 is the fastest and most affordable solution to protect IT gear from physical threats.
Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this exclusive easy-to-use cord retention method. While these cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled only when used with APC AP8000 series Rack PDUs or IT equipment with built-in locking receptacles. These locking connectors reduce the probability of accidentally disconnecting cords and dropping loads.SuguSisestatav konnektor/sisekonnektorToote värvKollane, MustKaabli pikkus0,6 mPistmik 1C13 pistikutPistmik 2C14 pistikutÜhenduse nurk90°RoHS-vastavusJahSisendvool10Kasutamistemperatuur (T-T)0 - 70 °CHoiustamistemperatuur (T-T)-25 - 75 °CSuhteline õhuniiskus kasutamisel (H-H)20 - 80 protsentiSuhteline õhuniiskus (H-H) hoiustamisel20 - 80 protsentiKasutamiskõrgus0 - 3000 mLaius70 mmSügavus40 mmKõrgus240 mmKaal700 g
PowerVAW: 1600 VA PowerW: 900 W Runtime: 10/2.5 Inputpinge: 140 - 300V Outputpinge: - InputFrequency: 50/60 Hz +/- 5 Hz Auto-sensing OutputFrequency: 50/60 Hz +/- 1 Hz Sync to mains InputConnections: - OutputConnections: - WaveformType: Stepped approximation to a sinewave RechargeTime: 8 h Patarei tüüp: Lead-acid Serial: - USB: Jah SmartSlot: - RJ45: - liidesPorts: USB ControlPanel: LED status display koos On joonOn Battery Alarm: Alarm when on batteryDistinctive low battery alarm värv: must Korpus: - Paki sisu: - laius: 140 mm sügavus: 390 mm kõrgus: 190 mm kaal: 10.300 kg Grosskaal: -
Double-conversion On-line UPS with Lithium-Ion battery to scalable runtime. Ideal UPS for essential power protection needs even in the most unstable power conditions. Includes: Basic UPS signalling RS-232 cable, Battery cable, C13-C14 power cord, Rack mounting brackets, Rack mounting support rails, RJ11 cable, RJ45 cable, Safety guide, Stabilization feet, USB cable, User manual