Available Distance *See SFP Specifications Back Plane 7.2Gbps Band width Control Supports Ingress and Egress Packet Limit Buffer 1Mbit Class Of Service Yes, Provides 4 Priority Queues per Port Configuration TFTP Configuration Backup & Restore DHCP DHCP Client/Server Functions Dimensions IP-30, 72 x 152 x 105 mm (2.83 x 5.98 x 4.13 inches) DNS DNS Client Feature and Primary & Secondary DNS Server EMI FCC Class A, CE-EN6100-4-2/3/4/5/6/8/11/12, CE-EN6100-6-2/4 Ethernet Port 16 x 10/100TX RJ-454 + 2 x 10/100/1000T (Combo Ports) Fault Output 1 Relay Output Fiber Port 2 x Mini-GBIC SFP Firmware Updates TFTP Firmware Update Flow Control Flow Control for Full-Duplex Back Pressure for Half-Duplex Free Fall IEC 60068-2-32 Gigabit Ethernet Port Yes, 2 x Ethernet or Mini-GBIC SFP Ports Humidity 5% ~ 95% non-condensing IEEE IEEE 802.3 10BaseT Ethernet IEEE 802.3u 100BaseTX IEEE 802.3ab 1000BaseT IEEE 802.3z Gigabit Fiber IEEE 802.3x Flow Control and Back-Pressure IEEE 802.3ad Port Trunking with LACP IEEE 802.1d Spanning Tree IEEE 802.1w Rapid Spanning Tree IEEE 802.1p Class of Service IEEE 802.1Q VLAN Tag IEEE 802.1x User Authentication (RADIUS) IGMP IGMP v1, v2, and Query Mode. Up to 256 Groups IP Security Supports up to 10 IP Addresses for Secured Access LED Port: Link/Activity, Full-Duplex/Collision, Speed Unit: Master, Power, Power1, Power2, Fault Login Security IEEE 802.1x Authentication/RADIUS Mac Address Table 8K MAC Address Table Management Yes, SNMP v1, v2c, v3, Web, Telnet, CLI Method Store and Forward Operating Temperature -40° ~ 80° C (-40° ~ 176° F) Port Mirroring TX, RX, or Both Packets Port Security 100 MAC Address Entries for Static MAC and 100 MAC Filters Port Trunk LACP Port Trunk: 4 Trunk Groups / Max. 4 Trunk Members Power Consumption 11.5 Watts Power Input 12 ~ 48 VDC Power Redundancy Yes Protocols CSMA/CD Quality Of Service Port, Tag, IPv4 Type of Service, IPv4 / IPv6 Different Service Reverse Polarity Yes RFC Standards RFC1215 Trap RFC1213 MIB II RFC1157 SNMP MIB RFC1493 Bridge MIB RFC2674 VLAN MIB RFC1643 RFC1757 RSTP MIB Private MIB Ring Recovery Time < 20ms Ring Redundancy Yes RS232 RJ-45 Type Safety UL/cUL Class I, Division 2 CE-EN60950-1 Shock IEC 60068-2-27 SMTP Yes SNMP Trap Yes SNTP Yes Spanning Tree Yes, 802.1d Spanning Tree & 802.1w Rapid Spanning Tree Storage Temperature -40° ~ 85° C System Event Log Yes Transfer Rate 14,880pps for Ethernet Port 148,800pps for Fast Ethernet Port 1,488,000pps for Gigabit Ethernet Port Vibration IEC 60068-2-6 VLAN Port Based and IEEE 802.1Q Tag VLAN Warranty 5 Years Wave length *See SFP Specifications
Features and Benefits 921.6 kbps maximum baudrate for super fast data transmission On-chip S/W flow control Built-in 15 kV ESD protection IRQ settings, I/O settings, and serial interface are jumper and DIP switch selectable Onboard Tx and Rx LED indicators for each port Windows CE 5.0/6.0 and Windows XP embedded operating systems supported Wide temperature model available for -40 to 85°C environments Overview The CA-134I PC/104 modules are reliable, high performance, multiport serial communication solutions that have 4 RS-422/485 ports, and can be used with PC/104 CPU boards that accept the PC/104 expansion interface. Optional DB9 and DB25 connection cables are available for connecting to serial devices, and the CA-134Is’ versatile driver support makes the modules suitable for a wide range of applications.• Hardware Comm. Controller 16C550C or compatible x 4 Bus PC/104 bus Connector 40-pin box header DIP Switches I/O base address, interrupt vector, serial interface• Serial Interface Number of Ports 4 Serial Standards RS-422/485 Max. No. of Boards per PC 4• Serial Line Protection ESD Protection 15 kV on the board Electrical Isolation 2 kV• Performance Baudrate 50 bps to 921.6 kbps• Serial Communication Parameters Data Bits 5, 6, 7, 8 Stop Bits 1, 1.5, 2 Parity None, Even, Odd, Space, Mark IRQ 3, 4, 5, 6, 7, 9, 10, 11, 12, 15 (shared for all ports) FIFO 64 bytes• Serial Signals RS-422 TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND RS-485-4w TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND RS-485-2w Data+(B), Data-(A), GND• Operating Systems Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008 (x86/x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded Fixed TTY Drivers QNX 4, QNX 6 Linux Real TTY Drivers Linux 2.4.x, 2.6.x Note Please refer to Moxa’s website for the latest driver support information.• Physical Characteristics Dimensions 90 x 96 mm (3.54 x 3.78 in)• Environmental Limits Operating Temperature Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) Storage Temperature -40 to 85°C (-40 to 185°F) Ambient Relative Humidity 5 to 95% (non-condensing) Altitude Up to 2000 m Note Please contact Moxa if you require products guaranteed to function properly at higher altitudes.• Standards and Certifications EMC CE, FCC EMI EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class A EMS EN 55024, IEC 61000-6-2, IEC 61000-6-4, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) Green Product RoHS, CRoHS, WEEE• MTBF (mean time between failures) Time 339,822 hrs Database Telcordia (Bellcore), GB• Power Requirements Power Consumption 220 mA @ 5 VDC• Warranty Warranty Period 5 years Details See www.moxa.com/warranty
Fluke 1625-2 on ainulaadne maandusmaanduse tester, mis suudab teostada kõiki nelja tüüpi maandusmaanduse mõõtmisi:3- ja 4-pooluseline fall-of-potential (vaiade abil).4-pooluseline pinnase takistuse testimine (kasutades panuseid).valikuline testimine (kasutades 1 klambrit ja panuseid).Vaakadeta testimine (kasutades ainult 2 klambrit) Reguleeritavad piirid - kiiremaks testimiseks.IP56 klassifikatsioon välitingimustes kasutamiseksVastupidav kandekottGeneral SpecificationsMemoryInternal memory storage up to 1500 records accessible via USB portMeasuring functionInterference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DCDisplay4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibilityOperationCentral rotary switch and function keysTemperature RangeOperating temperature-10°C to 50°C (14°F to 122°F)Storage temperature-30°C to 60°C (-22°F to 140°F)Temperature coefficient±0.1% of reading/°C < 18°C > 28°CType of protectionIP56 for case, IP40 for battery door according to EN60529Max voltageWarning – socket "clamp" to socket E, ES, S or HUrms = 0 VSockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse)SafetyProtection by double and/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2Quality standardDeveloped, designed and manufactured to comply with DIN ISO 9001External field influenceComplies with DIN 43780 (8/76)Auxiliary power6 x 1.5 V alkaline (IEC LR6 or type AA)Battery life spanWith IEC LR6/type AA: typ. 3,000 measurements (RE+RH ≤ 1 kΩ)With IEC LR6/type AA: typ. 6,000 measurements (RE + RH > 10 kΩ)Dimensions (W x H x D)250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)Weight≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying caseCase materialPolyesterMeasurement of Interference Voltage DC + AC (UST)Measuring limits of error: methodFull wave rectificationMeasuring range1 V to 50 VDisplay range0.0 V to 50 VResolution0.1 VFrequency rangeDC/AC 45 Hz to 400 Hz sineAccuracy±(5% of rdg + 5 digit)Measuring sequenceApprox. 4 measurements/sInternal resistanceApprox. 1.5 MΩMax. overloadUrms = 250 VMeasurement of Interference Frequency (F)Measuring limits of error: methodMeasurement of oscillation period of the interference voltageMeasuring range6.0 Hz to 400 HzDisplay range16.0 Hz to 299.9 Hz to 999 HzResolution0.1 Hz to 1 HzRange1 V to 50 VAccuracy±(1% of rdg + 2 digit)Earthing Resistance (RE)Measuring methodCurrent and voltage measurement with probe as IEC61557-5Open circuit voltage20/48 V, ACShort circuit current250 mA ACMeasuring frequency94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R1Noise rejection120 dB (16 2/3 , 50 , 60, 400 Hz)Max. overloadUrms = 250 VElectrical Measurement SpecificationsIntrinsic Error or Influence QuantityReference Conditions or Specified Operating RangeDesignation CodeRequirements or Test in Accordance with the Relevant Parts of IEC 1557Type of TestIntrinsic errorReference conditionsAPart 5, 6.1RPositionReference position ±90°E1Part 1, 4.2RSupply voltageAt the limits stated by the manufacturerE2Part 1, 4.2, 4.3RTemperature0°C and 35°CE3Part 1, 4.2TSeries interference voltageSee 4.2 and 4.3E4Part 5, 4.2, 4.3TResistance of the probes and auxiliary earth electrodes0 to 100 x RA but ≤ 50 kΩE5Part 5, 4.3TSystem frequency99% to 101% of the nominal frequencyE7Part 5, 4.3TSystem voltage85% to 110% of the nominal voltageE8Part 5, 4.3TOperating errorB = ±(|A| + 1,15 √E21 E22 E23 E24 E25 E26 )Part 5, 4.3RB[%] = ± B/fiducial value x 100%A = intrinsic errorEn = variationsR = routine testT = type testMeasuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω0.300 kΩ to 2.999 kΩ3.00 kΩ to 29.99 kΩ30.0 kΩ to 299.9 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 Ω100 ΩAccuracy±(2% of rdg + 2 digit)Operating error±(5% of rdg + 5 digit)Measuring timeTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequenciesAdditional error because of probe-and auxiliary earth electrode resistanceRH(RS + 2000 Ω)/RE x 1.25 x 10-6% + 5 digitsMeasuring error of RH and RSTyp. 10% of RE + RS + RHMax. probe resistance≤ 1 MΩMax. auxiliary earth electrode resistance≤ 1 MΩAutomatic check if error is kept within the limits required by IEC61557-5.If after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.Automatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance RHRH with Umeas = 48 V< 300 Ω< 6 Ω< 60 Ω< 600 ΩRH with Umeas = 20 V< 250 Ω< 2.5 kΩ< 25 kΩ< 250 kΩResolution1 mΩ10 mΩ100 mΩ1 ΩSelective Measurement of the Earthing Resistance (RE Clamp)Measuring methodCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).Open circuit voltage20/48 V ACShort circuit current250 mA ACMeasuring frequency94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R1)Noise rejection120 dB (162/3, 50, 60, 400 Hz)Max. overloadMax. Urms = 250 V (measurement will not be started)Measuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω0.300 kΩ to 2.999 kΩ3.00 kΩ to 29.99 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 ΩAccuracy±(7% of rdg + 2 digit)Operating error±(10% of rdg + 5 digit)Additional error because of probe- and auxiliary earth typ. electrode resistanceRH(RS + 2000 Ω)/RETOTAL x 1.25 x 10-6% + 5 digitsMeasuring error of RH and RSTyp. of 10% of RETOTAL + RS + RHMeasuring timeTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.Minimal current in single branch to be measured0.5 mAWith transformer (1000:1)0.1 mAWith transformer (200:1)Max. interference current through transformer3 AWith transformer (1000:1)1. With recommended current clamps/transformers.Resistance Measurement (R~)Measuring methodCurrent and voltage measurementMeasuring voltage20 V AC, square pulseShort circuit current> 250 mA ACMeasuring frequency94, 105, 111, 128 Hz selected manually or automatically (AFC)Measuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω300 Ω to 2999 Ω3.00 kΩ to 29.99 kΩ30.0 kΩ to 299.9 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 Ω100 ΩAccuracy±(2% of rdg + 2 digit)Operating error±(5% of rdg + 5 digit)Measuring timeTypical 6 secondsMax. interference voltage24 V, with higher voltages measurement will not be startedMax overloadUrms max. = 250 VResistance Measurement (R DC)Measuring methodCurrent- voltage measurement as per IEC61557-4 possibleMeasuring voltage20 V DCShort circuit current250 mA DCFormation of measured valueWith 4-pole measurement wires on H, S, ES can be extended without additional error.Resistances > 1 Ω in wire E can cause additional error of 5m Ω/Ω.Measuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω300 Ω to 2999 Ω3.0 kΩ to 29.99 kΩ30.0 kΩ to 299.9 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 Ω100 ΩAccuracy±(2% of rdg + 2 digit)Operating error±(5% of rdg + 5 digit)Measuring sequenceApprox. 2 measurements/sMeasuring timeTypical 4 second including reversal of polarity (2-pole or 4-pole)Maximum interference voltage≤ 3 V AC or DC, with higher voltages measurement will not be startedMaximum inductivity2 HenryMaximum overloadUrms = 250 VCompensation of Lead Resistance (RK)Compensation of lead resistance (RK) can be switched on in functions RE 3-pole, RE 4-pole (clamp), R AC, and R DC 2-poleFormation of measured valueRdisplay = Rmeasured - Rcompensated22. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.Stakeless Ground Loop Measurement (Two Clamp Stakeless)Switch positionRA 4-pole (two clamp Stakeless)Resolution0.001 Ω to 0.1 ΩMeasuring range0.02 Ω to 199.9 ΩAccuracy±(7% rdg + 3 digit)Operating error±(10% rdg + 5 digit)Measuring voltageVm = 48 V AC (primary)Measuring frequency128 HzNoise current (IEXT)Max. IEXT = 10 A (AC) (RA < 20 Ω)Max. IEXT = 2 A (AC) (RA > 20 Ω)Measuring principle: Stakeless measurement of resistance in closed loops using two current transformers.Automatic range selection.The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.
Fluke 117/323 elektrikute komplekt, digitaalne multimeeter ja klemm-mõõturÕigete tööriistade olemasolu on hädavajalik. Veelgi parem on, kui need on olemas just siis, kui neid vaja on. Fluke 117/323 elektrikute multimeetri ja klemm-mõõturi komplektiga olete igale tööobjektile valmis. Need kaks testimisvahendit annavad teile mitmekülgse ja vastupidava multimeetri võimsuse koos kiirelt toimiva universaalse klemm-mõõturiga.Sõltumata sellest, kas töötate elamute või ärihoonete elektrisüsteemidega, sobivad mõlemad testimisvahendid hästi teie tööde tegemiseks. Komplekt sisaldabFluke 117 digitaalmultimeeterFluke 323 klemm-mõõturTl175 testijuhidTPAK ToolPak magnetiline mõõturi riputiPehme kandekottFluke 117 digitaalmultimeeter on loodud teie elu lihtsustamiseks ja sisaldab järgmisi funktsioone:Kontaktivaba pinge tuvastamineAutoV/LoZ funktsioonMin/Max/keskmised näidudSageduse mõõtmineMahtuvuse mõõtmineEt tagada teie valmisolek töötamiseks paljudel töökohtadel, on 117 sertifitseeritud kasutamiseks CAT III 600 V keskkondades.Fluke 323 klemm-mõõtur on hea põhiline veaotsinguvahend äri- ja elamuehituse elektrikutele. See sisaldab tõelisi RMS-mõõtmisi, optimeeritud ergonoomikat ja suurt ekraani tõhusaks veaotsinguks. Väike klemm on loodud, et hõlbustada mõõtmisi kitsastes kaabelkambrites, ja sobib ideaalselt voolu mõõtmiseks kuni 400 A või pinge mõõtmiseks kuni 600 V.Fluke 117 elektriku multimeeter ja 323 tõelise RMS-klambrimõõtur annavad elektrikutele töö jaoks lihtsalt kasutatavad ja aega säästvad tööriistad.Fluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp MeterFluke 117 Digital MultimeterSpecificationsMaximum voltage between any terminal and earth ground600 VSurge protection6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)DisplayDigital: 6,000 counts, updates 4 per secondBar graph33 segments, updates 32 per secondOperating temperature-10 °C to +50 °CStorage temperature-40 °C to +60 °CBattery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61Battery life400 hours typical, without backlightAccuracy SpecificationsDC millivoltsRange/Resolution600.0 mV / 0.1 mVAccuracy±([% of reading] + [counts]): 0.5% + 2DC voltsRange/Resolution6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 VAccuracy±([% of reading] + [counts]): 0.5% + 2Auto voltsRange/Resolution600.0 V / 0.1 VAccuracy2.0% + 3 (DC, 45 Hz to 500 Hz)4.0% + 3 (500 Hz to 1 kHz)AC millivolts¹ True RMSRange/Resolution600.0 mV / 0.1 mVAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)AC volts¹ True RMSRange/Resolution6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 VAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)ContinuityRange/Resolution600 Ω / 1 ΩAccuracyBeeper on < 20 Ω, off > 250 Ω; detects opens or shorts of500 μs or longer.OhmsRange/Resolution600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩAccuracy0.9% + 1Range/Resolution40.00 MΩ / 0.01 MΩAccuracy5% + 2Diode testRange/Resolution2.00 V / 0.001 VAccuracy0.9% + 2CapacitanceRange/Resolution1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μFAccuracy1.9% + 2Range/Resolution> 1000 μFAccuracy5% + 20%Lo-Z capacitanceRange1 nF to 500 μFAccuracy10% + 2 typicalAC amps True RMS (45 Hz to 500 Hz)Range/Resolution6.000 A / 0.1 A10.00 A / 0.01 AAccuracy1.5% + 320 A continuous overload for 30 seconds maxDC ampsRange/Resolution6.000 A / 0.1 A10.00 A / 0.01 AAccuracy1.0% + 320 A continuous overload for 30 seconds maxHz (V or A input)²Range/Resolution99.99 Hz / 0.01 Hz999.99 Hz / 0.1 Hz9.999 Hz / 0.001 Hz50.00 Hz / 0.01 HzAccuracy0.1% + 21. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F.Mechanical and General SpecificationsSize167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)Weight550 gWarranty3 yearsFluke 323 True RMS Clamp MeterSpecificationsAC currentRange400.0 AAccuracy2% ±5 digits(45 Hz to 65 Hz)2.5% ±5 digits(65 Hz to 400 Hz)AC voltageRange600.0 VAccuracy1.5% ±5 digitsDC voltageRange600.0 VAccuracy1.0% ±5 digitsResistanceRange/Resolution400.0 Ω/ 4000 ΩAccuracy1.0% ±5 digitsContinuity≤ 70 ΩAC responseTrue RMSData holdYesSizeH x W x D (mm)207 x 75 x 34Max wire diameter30 mm (600 MCM)Weight265 gCategory ratingCAT III 600 VCAT IV 300 VWarrantyTwo-year
Fluke 117 multimeeter ja PRV240 kontrollseade komplektFluke 117 multimeeter ja PRV240 kontrollseade komplekt ühendab endas üldotstarbelise elektriku digitaalse multimeetri ja kaasaskantava, taskusse mahtuva, patareitoitega pingegeneraatori, mis võimaldab ohutult kontrollida, kas teie elektriline testimisseade töötab korralikult, enne kui teete pingelisi teste.Fluke 117 elektriku multimeeterFluke 117 elektrikute multimeeter sisaldab integreeritud kontaktivaba pinge tuvastamist, AutoVolt ja LoZ funktsioone kiiremate ja täpsemate näitude saamiseks. See on kompaktne tõeline RMS-mõõtur nõudlikele rakendustele, nagu ärihooned, haiglad ja koolid.Fluke 117 peamised funktsioonidIntegreeritud VoltAlert™ tehnoloogia kiireks kontaktivabaks pinge tuvastamiseks. Sisaldab AutoVolt automaatset vahelduvvoolu/alalisvoolu pinge valikutMadal sisendtakistus, mis aitab vältida vale näitude tekkimist varjupinge tõttuMin/Max/Average funktsioon signaali kõikumiste registreerimiseksCAT III 600 V ohutusklassPRV240 kontrollseadeFluke PRV240 kontrollseade on kaasaskantav, taskusse mahtuv, patareitoitega pingegeneraator. See on ainulaadne, kuna genereerib stabiilset vahelduv- ja alalisvoolu nii LoZ- kui ka HiZ-seadmetele.PRV240 kontrollseadme peamised funktsioonidÜks LED näitab seadme töökorrasolekut, muutes selle seadme lihtsaks lahenduseks teie testseadme TBT-kontrolli nõuete täitmiseks. Pinge allikaks on süvistatud kontaktid, mis aktiveeruvad testproovide sisestamisel, vältides juhuslikku kontakti.Komplektis TPak™ magnetiline riputusrihmPikk aku eluiga – 5000 testi nelja AA-aku komplektigaFluke 117 Multimeter and PRV240 Proving Unit KitSpecificationsMaximum voltage between any terminal and earth ground600 VSafetyIEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT III 600VFuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)DisplayDigital: 6,000 counts, updates 4 per secondBar graph33 segments, updates 32 per secondOperating temperature-10°C to +50°CStorage temperature-40°C to +60°CBattery type9 volt Alkaline, IEC 6LR61Battery life400 hours typical, without backlightAccuracy SpecificationsDC millivoltsRange/resolution600.0 mV / 0.1 mVAccuracy±([% of reading] + [counts]): 0.5% + 2DC voltsRange/resolution6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 VAccuracy±([% of reading] + [counts]): 0.5% + 2Auto voltsRange/resolution600.0 V / 0.1 VAccuracy2.0% + 3 (DC, 45 Hz to 500 Hz)4.0% + 3 (500 Hz to 1 kHz)AC millivolts¹ True RMSRange/resolution600.0 mV / 0.1 mVAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)AC volts¹ True RMSRange/resolution6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 VAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)ContinuityRange/resolution600 Ω / 1 ΩAccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.OhmsRange/resolutionOhms Range/resolution 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩAccuracy0.9% + 1Range/resolution40.00 MΩ / 0.01 MΩAccuracy5% + 2Diode testRange/resolutionAccuracy0.9% + 2CapacitanceRange/resolution1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μFAccuracy1.9% + 2Range/resolution> 1000 μFAccuracy5% + 20%Lo-Z capacitanceRange1 nF to 500 μFAccuracy10% + 2 typicalAC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A10.00 A / 0.01 AAccuracy1.5% + 320 A continuous overload for 30 seconds maxDC ampsRange/resolution6.000 A / 0.001 A 10.00 A / 0.01 AAccuracy1.0% + 320 A continuous overload for 30 seconds maxHz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 HzAccuracy0.1% + 21. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.Mechanical and General SpecificationsSize167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)Weight550 gWarranty3 yearsFluke PRV240 Proving UnitGeneral SpecificationsOutput voltage240 V ac rms or dc± 10 % ≥ 1 MΩLoZ >3 kΩ load60 V ac typical50 V ac rms minimumLED power indicatorTurns on when output voltage is presentBattery4 AA Alkaline batteries NEDA24 A IEC LR03Battery life5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ loadOperating temperature-10 °C to +50 °COperating humidity0 % to 90 % (0 °C to 35 °C)0 % to 70 % (35 °C to 55 °C)Operating altitude2000 mDimensions11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2Weight0.23 kg (8 oz) includes batteriesSafetyIEC61010-1, IEC61010-2-030WarrantyOne-yearElectromagnetic Compatibility (EMC)IEC 61326-1Portable EM environment; CISPR 11, Group 1, Class AUS (FCC)47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
See Delocki SATA-kaabel võimaldab ühendada erinevaid SATA-seadmeid, nt kõvakettaid, kontrollerikaarte või välkmälusid. See vastab uusimatele standarditele ja tagab andmeedastuskiiruse kuni 6 Gb/s. See on tagasiühilduv eelmiste SATA-versioonidega, kuid sel juhul saavutab ainult vastava andmeedastuskiiruse. Kui ühendate selle kaabli kõvakettaga, juhitakse kaabel allapoole. SpecificationSATA 6 Gb/sInterfaceConnector 11 x SATA 6 Gb/s 7 pin receptacle straightConnector 21 x SATA 6 Gb/s 7 Pin receptacle downwards angledTechnical characteristicsData transfer rateSATA up to 6 Gb/sPhysical characteristicsPin finishinggold-platedCable gauge26 AWGLength100 cmColourblue