Võrguseade MOXA Switch RS-422/485 PC/104 moodul, opt. isol. 2KV, -40 kuni +85°,4 porti
Tootekood: EE-100-184-143 Võrguseadmed
Features and Benefits 921.6 kbps maximum baudrate for super fast data transmission On-chip S/W flow control Built-in 15 kV ESD protection IRQ settings, I/O settings, and serial interface are jumper and DIP switch selectable Onboard Tx and Rx LED indicators for each port Windows CE 5.0/6.0 and Windows XP embedded operating systems supported Wide temperature model available for -40 to 85°C environments Overview The CA-134I PC/104 modules are reliable, high performance, multiport serial communication solutions that have 4 RS-422/485 ports, and can be used with PC/104 CPU boards that accept the PC/104 expansion interface. Optional DB9 and DB25 connection cables are available for connecting to serial devices, and the CA-134Is’ versatile driver support makes the modules suitable for a wide range of applications.• Hardware Comm. Controller 16C550C or compatible x 4 Bus PC/104 bus Connector 40-pin box header DIP Switches I/O base address, interrupt vector, serial interface• Serial Interface Number of Ports 4 Serial Standards RS-422/485 Max. No. of Boards per PC 4• Serial Line Protection ESD Protection 15 kV on the board Electrical Isolation 2 kV• Performance Baudrate 50 bps to 921.6 kbps• Serial Communication Parameters Data Bits 5, 6, 7, 8 Stop Bits 1, 1.5, 2 Parity None, Even, Odd, Space, Mark IRQ 3, 4, 5, 6, 7, 9, 10, 11, 12, 15 (shared for all ports) FIFO 64 bytes• Serial Signals RS-422 TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND RS-485-4w TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND RS-485-2w Data+(B), Data-(A), GND• Operating Systems Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008 (x86/x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded Fixed TTY Drivers QNX 4, QNX 6 Linux Real TTY Drivers Linux 2.4.x, 2.6.x Note Please refer to Moxa’s website for the latest driver support information.• Physical Characteristics Dimensions 90 x 96 mm (3.54 x 3.78 in)• Environmental Limits Operating Temperature Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) Storage Temperature -40 to 85°C (-40 to 185°F) Ambient Relative Humidity 5 to 95% (non-condensing) Altitude Up to 2000 m Note Please contact Moxa if you require products guaranteed to function properly at higher altitudes.• Standards and Certifications EMC CE, FCC EMI EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class A EMS EN 55024, IEC 61000-6-2, IEC 61000-6-4, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) Green Product RoHS, CRoHS, WEEE• MTBF (mean time between failures) Time 339,822 hrs Database Telcordia (Bellcore), GB• Power Requirements Power Consumption 220 mA @ 5 VDC• Warranty Warranty Period 5 years Details See www.moxa.com/warranty
1
612,56 €
1
1619,44 €
1
614,67 €
1
1592,16 €
1
2131,56 €
1
1838,92 €
1
6023,92 €
1
9016,78 €
1
300,08 €
1
310,00 €
1
436,48 €
1
724,16 €
1
1003,16 €
1
1003,16 €
1
1003,16 €
1
1003,16 €
1
626,20 €
1
874,20 €
1
1087,48 €
1
944,88 €
1
1275,96 €
1
500,96 €
1
28,52 €
1
147,56 €
1
86,80 €
1
9,92 €
1
946,12 €
1
2002,60 €
1
582,80 €
Thumbnail
Võrguseade Delock Adapter M.2 Key M - PCIe x4 NVMe nurgaga 0.2m
Tootekood: EE-100-191-217 Võrguseadmed
Seda Delocki adapterit saab kasutada PCI Express-kaardi ühendamiseks M.2 pesaga. Paindlik kaabel võimaldab ruumi säästvat paigaldamist arvuti korpuse sisse. Lisatoitepistikuga saab PCIe-kaarti vajadusel varustada 12 V pingega.GeneralFunctionNVM Express (NVMe)Bootable, ex UEFI 2.3.1InterfaceConnector 11 x 67 pin M.2 Key M maleConnector 21 x PCI Express x4, V3.0Connector 31 x 4 pin power connectorPhysical characteristicsCable length20 cm (without connector)
1
68,05 €
Thumbnail
Võrguseade MOXA Switch Switch: 8 x 10/100BaseT(X)C, -10 kuni 60°C, 12/24/48 VDC, manageeritav
Tootekood: EE-100-183-940 Võrguseadmed
EDS-4008 seeria on 8-portiline hallatav Fast Ethernet lüliti, millel on võimalus kasutada nelja 1 Gbps uplink-porti või kahte 100M ST/SC fiiberoptilist ühendust.porti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit.võimalusi suure ribalaiusega PoE-seadmete ühendamiseks.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavadteie võrgu magistraalvõrgu kättesaadavust. EDS-4008-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, näiteks video- ja protsessirakenduste jaoks.seire, ITS- ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4008-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii tooteturvalisust kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita turvalise tööstusvõrgu nõuetele vastavuse nõudeid.disainile.Ethernet Interface10/100BaseT(X) Ports (RJ45 connector)8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionStandardsIEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationOptical FiberEthernet Software FeaturesIndustrial ProtocolsEtherNet/IPModbus TCPPROFINET IO DeviceManagementIPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilterGMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy ProtocolsSTPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMSTPMRPSecurityBroadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSTACACS+Access control listLogin and Password PolicyDHCP SnoopingTime ManagementSNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017ProtocolsIPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIBP-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9Switch PropertiesMAC Table Size16 KJumbo Frame Size9.216 KBMax. No. of VLANs256VLAN ID RangeVID 1 to 4094IGMP Groups512Priority Queues4Packet Buffer Size1 MBLED InterfaceLED IndicatorsPWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCSerial InterfaceConsole PortRS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB InterfaceUSB ConnectorUSB Type A (Reserved)Input/Output InterfaceAlarm Contact Channels1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels1Digital Inputs+13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtonsReset buttonDIP Switch ConfigurationDIP SwitchesTurbo Ring, Master, Coupler, ReservePower ParametersConnection2 removable 4-contact terminal block(s)Pre-installed Power ModulePWR-100–LVNoteThe EDS-4008 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4008-T + PWR-100–LV = EDS-4008-LV-TEDS-4008-T + PWR-105-HV-I = EDS-4008-HV-TIf you install a different power module, refer to the specifications of the correspondingmodel. For example, if you replace the power module of the EDS-4008–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4008–HV-T.Input Voltage12/24/48 VDCRedundant dual inputsOperating Voltage9.6 to 60 VDCInput Current12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 APower Consumption (Max.)7.20 WOverload Current ProtectionSupportedReverse Polarity ProtectionSupportedPhysical CharacteristicsIP RatingIP40Dimensions55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight857 g (1.89 lb)InstallationDIN-rail mountingWall mounting (with optional kit)HousingMetalEnvironmental LimitsOperating Temperature-10 to 60°C (14 to 140°F)Storage Temperature (package included)-40 to 85°C (-40 to 185°F)Ambient Relative Humidity5 to 95% (non-condensing)Standards and CertificationsIndustrial CybersecurityIEC 62443-4-1IEC 62443-4-2SafetyUL 61010-2-201EN 62368-1 (LVD)EMCEN 55032/35EN 61000-6-2/-6-4EMICISPR 32, FCC Part 15B Class AEMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFMaritimeLRABSNKDNVVibrationIEC 60068-2-6ShockIEC 60068-2-27FreefallIEC 60068-2-32RailwayEN 50121-4Traffic ControlNEMA TS2Power SubstationIEC 61850-3IEEE 1613 Class 1Hazardous LocationsClass I Division 2ATEXIECExMTBFTime1,121,399 hrsStandardsTelcordia SR332WarrantyWarranty Period5 years
1
1257,36 €
Thumbnail
Võrguseade MOXA Switch Switch: 8 x 10/100BaseT(X)C, -40 kuni 75°C, 12/24/48 VDC, manageeritav
Tootekood: EE-100-183-941 Võrguseadmed
EDS-4008 seeria on 8-portiline hallatav Fast Ethernet lüliti, millel on võimalus kasutada nelja 1 Gbps uplink-porti või kahte 100M ST/SC fiiberoptilist ühendust.porti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit.võimalusi suure ribalaiusega PoE-seadmete ühendamiseks.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavadteie võrgu magistraalvõrgu kättesaadavust. EDS-4008-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, näiteks video- ja protsessirakenduste jaoks.seire, ITS- ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4008-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii tooteturvalisust kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita turvalise tööstusvõrgu nõuetele vastavuse nõudeid.disainile.Ethernet Interface10/100BaseT(X) Ports (RJ45 connector)8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionStandardsIEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationOptical FiberEthernet Software FeaturesIndustrial ProtocolsEtherNet/IPModbus TCPPROFINET IO DeviceManagementIPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilterGMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy ProtocolsSTPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMSTPMRPSecurityBroadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSTACACS+Access control listLogin and Password PolicyDHCP SnoopingTime ManagementSNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017ProtocolsIPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIBP-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9Switch PropertiesMAC Table Size16 KJumbo Frame Size9.216 KBMax. No. of VLANs256VLAN ID RangeVID 1 to 4094IGMP Groups512Priority Queues4Packet Buffer Size1 MBLED InterfaceLED IndicatorsPWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCSerial InterfaceConsole PortRS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB InterfaceUSB ConnectorUSB Type A (Reserved)Input/Output InterfaceAlarm Contact Channels1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels1Digital Inputs+13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtonsReset buttonDIP Switch ConfigurationDIP SwitchesTurbo Ring, Master, Coupler, ReservePower ParametersConnection2 removable 4-contact terminal block(s)Pre-installed Power ModulePWR-100–LVNoteThe EDS-4008 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4008-T + PWR-100–LV = EDS-4008-LV-TEDS-4008-T + PWR-105-HV-I = EDS-4008-HV-TIf you install a different power module, refer to the specifications of the correspondingmodel. For example, if you replace the power module of the EDS-4008–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4008–HV-T.Input Voltage12/24/48 VDCRedundant dual inputsOperating Voltage9.6 to 60 VDCInput Current12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 APower Consumption (Max.)7.20 WOverload Current ProtectionSupportedReverse Polarity ProtectionSupportedPhysical CharacteristicsIP RatingIP40Dimensions55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight857 g (1.89 lb)InstallationDIN-rail mountingWall mounting (with optional kit)HousingMetalEnvironmental LimitsOperating Temperature-40 to 75°C (-40 to 167°F)Storage Temperature (package included)-40 to 85°C (-40 to 185°F)Ambient Relative Humidity5 to 95% (non-condensing)Standards and CertificationsIndustrial CybersecurityIEC 62443-4-1IEC 62443-4-2SafetyUL 61010-2-201EN 62368-1 (LVD)EMCEN 55032/35EN 61000-6-2/-6-4EMICISPR 32, FCC Part 15B Class AEMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFMaritimeNKLRDNVABSVibrationIEC 60068-2-6ShockIEC 60068-2-27FreefallIEC 60068-2-32RailwayEN 50121-4Traffic ControlNEMA TS2Power SubstationIEC 61850-3IEEE 1613 Class 1Hazardous LocationsATEXClass I Division 2IECExMTBFTime1,121,399 hrsStandardsTelcordia SR332WarrantyWarranty Period5 years
1
1421,04 €
Thumbnail
Võrguseade MOXA Switch Switch: 8 x 10/100BaseT(X)C, -10 kuni 60°C, 110/220 VAC/VDC, manageeritav
Tootekood: EE-100-183-942 Võrguseadmed
EDS-4008 seeria on 8-portiline hallatav Fast Ethernet lüliti, millel on võimalus kasutada nelja 1 Gbps uplink-porti või kahte 100M ST/SC fiiberoptilist ühendust.porti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit.võimalusi suure ribalaiusega PoE-seadmete ühendamiseks.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavadteie võrgu magistraalvõrgu kättesaadavust. EDS-4008-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, näiteks video- ja protsessirakenduste jaoks.seire, ITS- ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4008-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii tooteturvalisust kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita turvalise tööstusvõrgu nõuetele vastavuse nõudeid.disainile.Ethernet Interface10/100BaseT(X) Ports (RJ45 connector)8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionStandardsIEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationOptical FiberEthernet Software FeaturesIndustrial ProtocolsEtherNet/IPModbus TCPPROFINET IO DeviceManagementIPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilterGMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy ProtocolsSTPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMSTPMRPSecurityBroadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSTACACS+Access control listLogin and Password PolicyDHCP SnoopingTime ManagementSNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017ProtocolsIPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIBP-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9Switch PropertiesMAC Table Size16 KJumbo Frame Size9.216 KBMax. No. of VLANs256VLAN ID RangeVID 1 to 4094IGMP Groups512Priority Queues4Packet Buffer Size1 MBLED InterfaceLED IndicatorsPWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCSerial InterfaceConsole PortRS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB InterfaceUSB ConnectorUSB Type A (Reserved)Input/Output InterfaceAlarm Contact Channels1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels1Digital Inputs+13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtonsReset buttonDIP Switch ConfigurationDIP SwitchesTurbo Ring, Master, Coupler, ReservePower ParametersConnection2 removable 4-contact terminal block(s)Pre-installed Power ModulePWR-105-HV-INoteThe EDS-4008 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4008-T + PWR-100–LV = EDS-4008-LV-TEDS-4008-T + PWR-105-HV-I = EDS-4008-HV-TIf you install a different power module, refer to the specifications of the correspondingmodel. For example, if you replace the power module of the EDS-4008–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4008–HV-T.Input Voltage110/220 VDC/VACSingle inputOperating Voltage88 to 300 VDC, 85 to 264 VACInput Current110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 APower Consumption (Max.)8.13 WOverload Current ProtectionSupportedReverse Polarity ProtectionSupportedPhysical CharacteristicsIP RatingIP40Dimensions55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight857 g (1.89 lb)InstallationDIN-rail mountingWall mounting (with optional kit)HousingMetalEnvironmental LimitsOperating Temperature-40 to 75°C (-40 to 167°F)Storage Temperature (package included)-40 to 85°C (-40 to 185°F)Ambient Relative Humidity5 to 95% (non-condensing)Standards and CertificationsIndustrial CybersecurityIEC 62443-4-1IEC 62443-4-2SafetyUL 61010-2-201EN 62368-1 (LVD)EMCEN 55032/35EN 61000-6-2/-6-4EMICISPR 32, FCC Part 15B Class AEMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFVibrationIEC 60068-2-6ShockIEC 60068-2-27FreefallIEC 60068-2-32RailwayEN 50121-4Traffic ControlNEMA TS2Power SubstationIEC 61850-3IEEE 1613 Class 1MTBFTime513,575 hrsStandardsTelcordia SR332WarrantyWarranty Period5 years
1
1393,76 €
Thumbnail
Võrguseade MOXA Switch Switch: 8 x 10/100BaseT(X)C, -40 kuni 75°C, 110/220 VAC/VDC, manageeritav
Tootekood: EE-100-183-943 Võrguseadmed
EDS-4008 seeria on 8-portiline hallatav Fast Ethernet lüliti, millel on võimalus kasutada nelja 1 Gbps uplink-porti või kahte 100M ST/SC fiiberoptilist ühendust.porti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit.võimalusi suure ribalaiusega PoE-seadmete ühendamiseks.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavadteie võrgu magistraalvõrgu kättesaadavust. EDS-4008-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, näiteks video- ja protsessirakenduste jaoks.seire, ITS- ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4008-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii tooteturvalisust kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita turvalise tööstusvõrgu nõuetele vastavuse nõudeid.disainile.Ethernet Interface10/100BaseT(X) Ports (RJ45 connector)8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionStandardsIEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationOptical FiberEthernet Software FeaturesIndustrial ProtocolsEtherNet/IPModbus TCPPROFINET IO DeviceManagementIPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilterGMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy ProtocolsSTPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMSTPMRPSecurityBroadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSTACACS+Access control listLogin and Password PolicyDHCP SnoopingTime ManagementSNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017ProtocolsIPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIBP-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9Switch PropertiesMAC Table Size16 KJumbo Frame Size9.216 KBMax. No. of VLANs256VLAN ID RangeVID 1 to 4094IGMP Groups512Priority Queues4Packet Buffer Size1 MBLED InterfaceLED IndicatorsPWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCSerial InterfaceConsole PortRS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB InterfaceUSB ConnectorUSB Type A (Reserved)Input/Output InterfaceAlarm Contact Channels1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels1Digital Inputs+13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtonsReset buttonDIP Switch ConfigurationDIP SwitchesTurbo Ring, Master, Coupler, ReservePower ParametersConnection2 removable 4-contact terminal block(s)Pre-installed Power ModulePWR-105-HV-INoteThe EDS-4008 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4008-T + PWR-100–LV = EDS-4008-LV-TEDS-4008-T + PWR-105-HV-I = EDS-4008-HV-TIf you install a different power module, refer to the specifications of the correspondingmodel. For example, if you replace the power module of the EDS-4008–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4008–HV-T.Input Voltage110/220 VDC/VACSingle inputOperating Voltage88 to 300 VDC, 85 to 264 VACInput Current110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 APower Consumption (Max.)8.13 WOverload Current ProtectionSupportedReverse Polarity ProtectionSupportedPhysical CharacteristicsIP RatingIP40Dimensions55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight857 g (1.89 lb)InstallationDIN-rail mountingWall mounting (with optional kit)HousingMetalEnvironmental LimitsOperating Temperature-40 to 75°C (-40 to 167°F)Storage Temperature (package included)-40 to 85°C (-40 to 185°F)Ambient Relative Humidity5 to 95% (non-condensing)Standards and CertificationsIndustrial CybersecurityIEC 62443-4-1IEC 62443-4-2SafetyUL 61010-2-201EN 62368-1 (LVD)EMCEN 55032/35EN 61000-6-2/-6-4EMICISPR 32, FCC Part 15B Class AEMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFVibrationIEC 60068-2-6ShockIEC 60068-2-27FreefallIEC 60068-2-32RailwayEN 50121-4Traffic ControlNEMA TS2Power SubstationIEC 61850-3IEEE 1613 Class 1MTBFTime513,575 hrsStandardsTelcordia SR332WarrantyWarranty Period5 years
1
1553,72 €
Thumbnail
Võrguseade MOXA Switch: 8 x 10/100BaseT(X), 4 x 100/1000BaseSFP, -10 kuni 60°C, dual 12/24/48 VDC, manageeritav
Tootekood: EE-100-183-970 Võrguseadmed
Välja töötatud vastavalt standardile IEC 62443-4-1 ja kooskõlas tööstusliku küberturvalisuse standardiga IEC 62443-4-2.Toetab IEEE 802.3bt PoE-d kuni 90 W väljundvõimsusega pordi kohta.Turbo Ring ja Turbo Chain (taastumisaeg < 20 ms @ 250 lülitit) , ja RSTP/STP võrgu redundantsi tagamiseks.Lai valik toiteallikaid paindlikuks kasutuselevõtuksKompaktne ja paindlik korpuse disain, mis sobib piiratud ruumidesseToetab MXstudio't lihtsaks, visualiseeritud tööstusvõrgu haldamiseksEDS-4012-seeria on 12-portiline hallatavate Fast Ethernet-kommutaatorite seeria, millel on võimalus kasutada nelja 1 Gbit/s kiudoptilist üleslüliporti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit, et ühendada suure ribalaiusega PoE-seadmeid.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavad võrgu magistraalvõrgu kättesaadavust. EDS-4012-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, nagu video- ja protsesside jälgimine, ITS ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4012-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii toote turvalisuse kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita tööstuslike võrkude turvalise projekteerimise nõuetele vastavust.10/100BaseT(X) Ports (RJ45 connector) EDS-4012-4GS-LV/-HV/-T models: 8EDS-4012-4GC-LV/-HV/-T models: 8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionPoE Ports (10/100BaseT(X), RJ45 connector) EDS-4012-8P-4GS-LVA/-LVB/-T models: 8100/1000BaseSFP Ports EDS-4012-4GS-LV/-HV/-T models: 4EDS-4012-8P-4GS-LVA/-VB/-T models: 4Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP) EDS-4012-4GC-LV/-HV/-T models: 4Standards IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationIndustrial Protocols EtherNet/IPModbus TCPPROFINET IO DeviceManagement IPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilter GMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy Protocols STPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMRPMSTPSecurity Broadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSDHCP SnoopingTACACS+Login and Password PolicyAccess control listTime Management SNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017Protocols IPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIB P-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9MAC Table Size 16 KJumbo Frame Size 9.216 KBMax. No. of VLANs 256VLAN ID Range VID 1 to 4094IGMP Groups 512Priority Queues 4Packet Buffer Size 1 MBLED Indicators PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCConsole Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB Connector USB Type A (Reserved)Alarm Contact Channels 1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels 1Digital Inputs +13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtons Reset buttonDIP Switches Turbo Ring, Master, Coupler, ReserveConnection 2 removable 4-contact terminal block(s)Pre-installed Power Module -LV/-LV-T models: PWR-100–LV-HV/-HV-T models: PWR-105-HV-I-LVA/-LVA-T models: PWR-101-LV-BP-I-LVB/-LVB-T models: PWR-103-LV-VB-INote The EDS-4012 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4012-4GS-T + PWR-100–LV = EDS-4012-4GS-LV-TEDS-4012-4GS-T + PWR-105-HV-I = EDS-4012-4GS-HV-TIf you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4012-4GS–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4012–4GS-HV-T.Input Voltage -LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs-HV/-HV-T models: 110/220 VDC/VAC, Single input-LVA/-LVA-T models: 48 VDC, Redundant dual inputs-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputsOperating Voltage -LV/-LV-T models: 9.6 to 60 VDC-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC-LVA/-LVA-T models: 44 to 57 VDC (>52 VDC for PoE+ output recommended)-LVB/-LVB-T models: 12 to 57 VDC (>52 VDC for PoE+ output recommended)Input Current -LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A-LVA/-LVA-T models: 48 VDC, 5.42 A-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 APower Consumption (Max.) EDS-4012-4GS-LV/-T models: 10.52 WEDS-4012-4GS-HV-/T models: 12.22 WEDS-4012-4GC-LV/-T models: 10.7 WEDS-4012-4GC-HV/-T models: 13.35 WEDS-4012-8P-4GS-LVA/-T models:Without PoE: 13.34 WWith PoE: Max. 240 W for total PD power consumption @ 48 VDC inputEDS-4012-8P-4GS-LVB/-T models:Without PoE: 15.32 WWith PoE:Max. 180 W for total PD power consumption @ 48 VDC inputMax. 150 W for total PD power consumption @ 24 VDC input (Max. 120 W for -T model)Max. 62 W for total PD consumption @ 12 VDC inputMax. PoE Power Output per Port 90 WOverload Current Protection SupportedReverse Polarity Protection SupportedIP Rating IP40Dimensions 55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight 827 g (1.82 lb)Installation DIN-rail mountingWall mounting (with optional kit)Housing MetalOperating Temperature Standard Models: -10 to 60°C (14 to 140°F)Wide Temp. Models: -40 to 75°C (-40 to 167°F)Storage Temperature (package included) -40 to 85°C (-40 to 185°F)Ambient Relative Humidity 5 to 95% (non-condensing)Industrial Cybersecurity IEC 62443-4-1IEC 62443-4-2Safety UL 61010-2-201EN 62368-1 (LVD)EMC EN 55032/35EN 61000-6-2/-6-4EMI CISPR 32, FCC Part 15B Class AEMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFMaritime -LV/-LV-T, PoE/PoE-T models: DNV, ABS, NK, LRVibration IEC 60068-2-6Shock IEC 60068-2-27Freefall IEC 60068-2-32Railway EN 50121-4Traffic Control NEMA TS2Power Substation IEC 61850-3IEEE 1613 Class 1Hazardous Locations -LV/-LV-T models:ATEXIECExClass I Division 2Time EDS-4012-4GC-LV/-T models: 1,036,336 hrsEDS-4012-4GC-HV/-T models: 497,392 hrsEDS-4012-4GS-LV/-T models: 874,838 hrsEDS-4012-4GS-HV/-T models: 456,870 hrsEDS-4012-8P-4GS-LVA/-T models: 799,780 hrsEDS-4012-8P-4GS-LVB/-T models: 759,924 hrsStandards Telcordia SR332Warranty Period 5 years
1
1618,20 €
Thumbnail
Võrguseade MOXA Switch: 8 x 10/100BaseT(X), 4 x 100/1000BaseSFP, -40 kuni 75°C, dual 12/24/48 VDC, manageeritav
Tootekood: EE-100-183-971 Võrguseadmed
Välja töötatud vastavalt standardile IEC 62443-4-1 ja kooskõlas tööstusliku küberturvalisuse standardiga IEC 62443-4-2.Toetab IEEE 802.3bt PoE-d kuni 90 W väljundvõimsusega pordi kohta.Turbo Ring ja Turbo Chain (taastumisaeg < 20 ms @ 250 lülitit) , ja RSTP/STP võrgu redundantsi tagamiseks.Lai valik toiteallikaid paindlikuks kasutuselevõtuksKompaktne ja paindlik korpuse disain, mis sobib piiratud ruumidesseToetab MXstudio't lihtsaks, visualiseeritud tööstusvõrgu haldamiseksEDS-4012-seeria on 12-portiline hallatavate Fast Ethernet-kommutaatorite seeria, millel on võimalus kasutada nelja 1 Gbit/s kiudoptilist üleslüliporti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit, et ühendada suure ribalaiusega PoE-seadmeid.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavad võrgu magistraalvõrgu kättesaadavust. EDS-4012-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, nagu video- ja protsesside jälgimine, ITS ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4012-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii toote turvalisuse kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita tööstuslike võrkude turvalise projekteerimise nõuetele vastavust.10/100BaseT(X) Ports (RJ45 connector) EDS-4012-4GS-LV/-HV/-T models: 8EDS-4012-4GC-LV/-HV/-T models: 8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionPoE Ports (10/100BaseT(X), RJ45 connector) EDS-4012-8P-4GS-LVA/-LVB/-T models: 8100/1000BaseSFP Ports EDS-4012-4GS-LV/-HV/-T models: 4EDS-4012-8P-4GS-LVA/-VB/-T models: 4Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP) EDS-4012-4GC-LV/-HV/-T models: 4Standards IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationIndustrial Protocols EtherNet/IPModbus TCPPROFINET IO DeviceManagement IPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilter GMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy Protocols STPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMRPMSTPSecurity Broadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSDHCP SnoopingTACACS+Login and Password PolicyAccess control listTime Management SNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017Protocols IPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIB P-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9MAC Table Size 16 KJumbo Frame Size 9.216 KBMax. No. of VLANs 256VLAN ID Range VID 1 to 4094IGMP Groups 512Priority Queues 4Packet Buffer Size 1 MBLED Indicators PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCConsole Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB Connector USB Type A (Reserved)Alarm Contact Channels 1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels 1Digital Inputs +13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtons Reset buttonDIP Switches Turbo Ring, Master, Coupler, ReserveConnection 2 removable 4-contact terminal block(s)Pre-installed Power Module -LV/-LV-T models: PWR-100–LV-HV/-HV-T models: PWR-105-HV-I-LVA/-LVA-T models: PWR-101-LV-BP-I-LVB/-LVB-T models: PWR-103-LV-VB-INote The EDS-4012 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4012-4GS-T + PWR-100–LV = EDS-4012-4GS-LV-TEDS-4012-4GS-T + PWR-105-HV-I = EDS-4012-4GS-HV-TIf you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4012-4GS–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4012–4GS-HV-T.Input Voltage -LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs-HV/-HV-T models: 110/220 VDC/VAC, Single input-LVA/-LVA-T models: 48 VDC, Redundant dual inputs-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputsOperating Voltage -LV/-LV-T models: 9.6 to 60 VDC-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC-LVA/-LVA-T models: 44 to 57 VDC (>52 VDC for PoE+ output recommended)-LVB/-LVB-T models: 12 to 57 VDC (>52 VDC for PoE+ output recommended)Input Current -LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A-LVA/-LVA-T models: 48 VDC, 5.42 A-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 APower Consumption (Max.) EDS-4012-4GS-LV/-T models: 10.52 WEDS-4012-4GS-HV-/T models: 12.22 WEDS-4012-4GC-LV/-T models: 10.7 WEDS-4012-4GC-HV/-T models: 13.35 WEDS-4012-8P-4GS-LVA/-T models:Without PoE: 13.34 WWith PoE: Max. 240 W for total PD power consumption @ 48 VDC inputEDS-4012-8P-4GS-LVB/-T models:Without PoE: 15.32 WWith PoE:Max. 180 W for total PD power consumption @ 48 VDC inputMax. 150 W for total PD power consumption @ 24 VDC input (Max. 120 W for -T model)Max. 62 W for total PD consumption @ 12 VDC inputMax. PoE Power Output per Port 90 WOverload Current Protection SupportedReverse Polarity Protection SupportedIP Rating IP40Dimensions 55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight 827 g (1.82 lb)Installation DIN-rail mountingWall mounting (with optional kit)Housing MetalOperating Temperature Standard Models: -10 to 60°C (14 to 140°F)Wide Temp. Models: -40 to 75°C (-40 to 167°F)Storage Temperature (package included) -40 to 85°C (-40 to 185°F)Ambient Relative Humidity 5 to 95% (non-condensing)Industrial Cybersecurity IEC 62443-4-1IEC 62443-4-2Safety UL 61010-2-201EN 62368-1 (LVD)EMC EN 55032/35EN 61000-6-2/-6-4EMI CISPR 32, FCC Part 15B Class AEMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFMaritime -LV/-LV-T, PoE/PoE-T models: DNV, ABS, NK, LRVibration IEC 60068-2-6Shock IEC 60068-2-27Freefall IEC 60068-2-32Railway EN 50121-4Traffic Control NEMA TS2Power Substation IEC 61850-3IEEE 1613 Class 1Hazardous Locations -LV/-LV-T models:ATEXIECExClass I Division 2Time EDS-4012-4GC-LV/-T models: 1,036,336 hrsEDS-4012-4GC-HV/-T models: 497,392 hrsEDS-4012-4GS-LV/-T models: 874,838 hrsEDS-4012-4GS-HV/-T models: 456,870 hrsEDS-4012-8P-4GS-LVA/-T models: 799,780 hrsEDS-4012-8P-4GS-LVB/-T models: 759,924 hrsStandards Telcordia SR332Warranty Period 5 years
1
1779,40 €
Thumbnail
Võrguseade MOXA Switch: 8 x 10/100BaseT(X), 4 x 100/1000BaseSFP, -10 kuni 60°C, 110/220 VAC/VDC, manageeritav
Tootekood: EE-100-183-972 Võrguseadmed
Välja töötatud vastavalt standardile IEC 62443-4-1 ja kooskõlas tööstusliku küberturvalisuse standardiga IEC 62443-4-2.Toetab IEEE 802.3bt PoE-d kuni 90 W väljundvõimsusega pordi kohta.Turbo Ring ja Turbo Chain (taastumisaeg < 20 ms @ 250 lülitit) , ja RSTP/STP võrgu redundantsi tagamiseks.Lai valik toiteallikaid paindlikuks kasutuselevõtuksKompaktne ja paindlik korpuse disain, mis sobib piiratud ruumidesseToetab MXstudio't lihtsaks, visualiseeritud tööstusvõrgu haldamiseksEDS-4012-seeria on 12-portiline hallatavate Fast Ethernet-kommutaatorite seeria, millel on võimalus kasutada nelja 1 Gbit/s kiudoptilist üleslüliporti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit, et ühendada suure ribalaiusega PoE-seadmeid.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavad võrgu magistraalvõrgu kättesaadavust. EDS-4012-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, nagu video- ja protsesside jälgimine, ITS ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4012-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii toote turvalisuse kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita tööstuslike võrkude turvalise projekteerimise nõuetele vastavust.10/100BaseT(X) Ports (RJ45 connector) EDS-4012-4GS-LV/-HV/-T models: 8EDS-4012-4GC-LV/-HV/-T models: 8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionPoE Ports (10/100BaseT(X), RJ45 connector) EDS-4012-8P-4GS-LVA/-LVB/-T models: 8100/1000BaseSFP Ports EDS-4012-4GS-LV/-HV/-T models: 4EDS-4012-8P-4GS-LVA/-VB/-T models: 4Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP) EDS-4012-4GC-LV/-HV/-T models: 4Standards IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationIndustrial Protocols EtherNet/IPModbus TCPPROFINET IO DeviceManagement IPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilter GMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy Protocols STPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMRPMSTPSecurity Broadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSDHCP SnoopingTACACS+Login and Password PolicyAccess control listTime Management SNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017Protocols IPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIB P-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9MAC Table Size 16 KJumbo Frame Size 9.216 KBMax. No. of VLANs 256VLAN ID Range VID 1 to 4094IGMP Groups 512Priority Queues 4Packet Buffer Size 1 MBLED Indicators PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCConsole Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB Connector USB Type A (Reserved)Alarm Contact Channels 1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels 1Digital Inputs +13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtons Reset buttonDIP Switches Turbo Ring, Master, Coupler, ReserveConnection 2 removable 4-contact terminal block(s)Pre-installed Power Module -LV/-LV-T models: PWR-100–LV-HV/-HV-T models: PWR-105-HV-I-LVA/-LVA-T models: PWR-101-LV-BP-I-LVB/-LVB-T models: PWR-103-LV-VB-INote The EDS-4012 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4012-4GS-T + PWR-100–LV = EDS-4012-4GS-LV-TEDS-4012-4GS-T + PWR-105-HV-I = EDS-4012-4GS-HV-TIf you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4012-4GS–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4012–4GS-HV-T.Input Voltage -LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs-HV/-HV-T models: 110/220 VDC/VAC, Single input-LVA/-LVA-T models: 48 VDC, Redundant dual inputs-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputsOperating Voltage -LV/-LV-T models: 9.6 to 60 VDC-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC-LVA/-LVA-T models: 44 to 57 VDC (>52 VDC for PoE+ output recommended)-LVB/-LVB-T models: 12 to 57 VDC (>52 VDC for PoE+ output recommended)Input Current -LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A-LVA/-LVA-T models: 48 VDC, 5.42 A-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 APower Consumption (Max.) EDS-4012-4GS-LV/-T models: 10.52 WEDS-4012-4GS-HV-/T models: 12.22 WEDS-4012-4GC-LV/-T models: 10.7 WEDS-4012-4GC-HV/-T models: 13.35 WEDS-4012-8P-4GS-LVA/-T models:Without PoE: 13.34 WWith PoE: Max. 240 W for total PD power consumption @ 48 VDC inputEDS-4012-8P-4GS-LVB/-T models:Without PoE: 15.32 WWith PoE:Max. 180 W for total PD power consumption @ 48 VDC inputMax. 150 W for total PD power consumption @ 24 VDC input (Max. 120 W for -T model)Max. 62 W for total PD consumption @ 12 VDC inputMax. PoE Power Output per Port 90 WOverload Current Protection SupportedReverse Polarity Protection SupportedIP Rating IP40Dimensions 55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight 827 g (1.82 lb)Installation DIN-rail mountingWall mounting (with optional kit)Housing MetalOperating Temperature Standard Models: -10 to 60°C (14 to 140°F)Wide Temp. Models: -40 to 75°C (-40 to 167°F)Storage Temperature (package included) -40 to 85°C (-40 to 185°F)Ambient Relative Humidity 5 to 95% (non-condensing)Industrial Cybersecurity IEC 62443-4-1IEC 62443-4-2Safety UL 61010-2-201EN 62368-1 (LVD)EMC EN 55032/35EN 61000-6-2/-6-4EMI CISPR 32, FCC Part 15B Class AEMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFMaritime -LV/-LV-T, PoE/PoE-T models: DNV, ABS, NK, LRVibration IEC 60068-2-6Shock IEC 60068-2-27Freefall IEC 60068-2-32Railway EN 50121-4Traffic Control NEMA TS2Power Substation IEC 61850-3IEEE 1613 Class 1Hazardous Locations -LV/-LV-T models:ATEXIECExClass I Division 2Time EDS-4012-4GC-LV/-T models: 1,036,336 hrsEDS-4012-4GC-HV/-T models: 497,392 hrsEDS-4012-4GS-LV/-T models: 874,838 hrsEDS-4012-4GS-HV/-T models: 456,870 hrsEDS-4012-8P-4GS-LVA/-T models: 799,780 hrsEDS-4012-8P-4GS-LVB/-T models: 759,924 hrsStandards Telcordia SR332Warranty Period 5 years
1
1750,88 €
Thumbnail
Võrguseade MOXA Switch: 8 x 10/100BaseT(X), 4 x 10/100/1000BaseT(X) või 100/1000BaseSFP, -10 kuni 60°C, dual 12/24/48 VDC, manageeritav
Tootekood: EE-100-183-974 Võrguseadmed
Välja töötatud vastavalt standardile IEC 62443-4-1 ja kooskõlas tööstusliku küberturvalisuse standardiga IEC 62443-4-2.Toetab IEEE 802.3bt PoE-d kuni 90 W väljundvõimsusega pordi kohta.Turbo Ring ja Turbo Chain (taastumisaeg < 20 ms @ 250 lülitit) , ja RSTP/STP võrgu redundantsi tagamiseks.Lai valik toiteallikaid paindlikuks kasutuselevõtuksKompaktne ja paindlik korpuse disain, mis sobib piiratud ruumidesseToetab MXstudio't lihtsaks, visualiseeritud tööstusvõrgu haldamiseksEDS-4012-seeria on 12-portiline hallatavate Fast Ethernet-kommutaatorite seeria, millel on võimalus kasutada nelja 1 Gbit/s kiudoptilist üleslüliporti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit, et ühendada suure ribalaiusega PoE-seadmeid.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavad võrgu magistraalvõrgu kättesaadavust. EDS-4012-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, nagu video- ja protsesside jälgimine, ITS ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4012-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii toote turvalisuse kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita tööstuslike võrkude turvalise projekteerimise nõuetele vastavust.10/100BaseT(X) Ports (RJ45 connector) EDS-4012-4GS-LV/-HV/-T models: 8EDS-4012-4GC-LV/-HV/-T models: 8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionPoE Ports (10/100BaseT(X), RJ45 connector) EDS-4012-8P-4GS-LVA/-LVB/-T models: 8100/1000BaseSFP Ports EDS-4012-4GS-LV/-HV/-T models: 4EDS-4012-8P-4GS-LVA/-VB/-T models: 4Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP) EDS-4012-4GC-LV/-HV/-T models: 4Standards IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationIndustrial Protocols EtherNet/IPModbus TCPPROFINET IO DeviceManagement IPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilter GMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy Protocols STPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMRPMSTPSecurity Broadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSDHCP SnoopingTACACS+Login and Password PolicyAccess control listTime Management SNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017Protocols IPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIB P-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9MAC Table Size 16 KJumbo Frame Size 9.216 KBMax. No. of VLANs 256VLAN ID Range VID 1 to 4094IGMP Groups 512Priority Queues 4Packet Buffer Size 1 MBLED Indicators PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCConsole Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB Connector USB Type A (Reserved)Alarm Contact Channels 1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels 1Digital Inputs +13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtons Reset buttonDIP Switches Turbo Ring, Master, Coupler, ReserveConnection 2 removable 4-contact terminal block(s)Pre-installed Power Module -LV/-LV-T models: PWR-100–LV-HV/-HV-T models: PWR-105-HV-I-LVA/-LVA-T models: PWR-101-LV-BP-I-LVB/-LVB-T models: PWR-103-LV-VB-INote The EDS-4012 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4012-4GS-T + PWR-100–LV = EDS-4012-4GS-LV-TEDS-4012-4GS-T + PWR-105-HV-I = EDS-4012-4GS-HV-TIf you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4012-4GS–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4012–4GS-HV-T.Input Voltage -LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs-HV/-HV-T models: 110/220 VDC/VAC, Single input-LVA/-LVA-T models: 48 VDC, Redundant dual inputs-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputsOperating Voltage -LV/-LV-T models: 9.6 to 60 VDC-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC-LVA/-LVA-T models: 44 to 57 VDC (>52 VDC for PoE+ output recommended)-LVB/-LVB-T models: 12 to 57 VDC (>52 VDC for PoE+ output recommended)Input Current -LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A-LVA/-LVA-T models: 48 VDC, 5.42 A-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 APower Consumption (Max.) EDS-4012-4GS-LV/-T models: 10.52 WEDS-4012-4GS-HV-/T models: 12.22 WEDS-4012-4GC-LV/-T models: 10.7 WEDS-4012-4GC-HV/-T models: 13.35 WEDS-4012-8P-4GS-LVA/-T models:Without PoE: 13.34 WWith PoE: Max. 240 W for total PD power consumption @ 48 VDC inputEDS-4012-8P-4GS-LVB/-T models:Without PoE: 15.32 WWith PoE:Max. 180 W for total PD power consumption @ 48 VDC inputMax. 150 W for total PD power consumption @ 24 VDC input (Max. 120 W for -T model)Max. 62 W for total PD consumption @ 12 VDC inputMax. PoE Power Output per Port 90 WOverload Current Protection SupportedReverse Polarity Protection SupportedIP Rating IP40Dimensions 55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight 827 g (1.82 lb)Installation DIN-rail mountingWall mounting (with optional kit)Housing MetalOperating Temperature Standard Models: -10 to 60°C (14 to 140°F)Wide Temp. Models: -40 to 75°C (-40 to 167°F)Storage Temperature (package included) -40 to 85°C (-40 to 185°F)Ambient Relative Humidity 5 to 95% (non-condensing)Industrial Cybersecurity IEC 62443-4-1IEC 62443-4-2Safety UL 61010-2-201EN 62368-1 (LVD)EMC EN 55032/35EN 61000-6-2/-6-4EMI CISPR 32, FCC Part 15B Class AEMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFMaritime -LV/-LV-T, PoE/PoE-T models: DNV, ABS, NK, LRVibration IEC 60068-2-6Shock IEC 60068-2-27Freefall IEC 60068-2-32Railway EN 50121-4Traffic Control NEMA TS2Power Substation IEC 61850-3IEEE 1613 Class 1Hazardous Locations -LV/-LV-T models:ATEXIECExClass I Division 2Time EDS-4012-4GC-LV/-T models: 1,036,336 hrsEDS-4012-4GC-HV/-T models: 497,392 hrsEDS-4012-4GS-LV/-T models: 874,838 hrsEDS-4012-4GS-HV/-T models: 456,870 hrsEDS-4012-8P-4GS-LVA/-T models: 799,780 hrsEDS-4012-8P-4GS-LVB/-T models: 759,924 hrsStandards Telcordia SR332Warranty Period 5 years
1
1750,88 €
Thumbnail
Võrguseade MOXA Switch: 8 x 10/100BaseT(X), 4 x 10/100/1000BaseT(X) või 100/1000BaseSFP, -10 kuni 60°C, 110/220 VAC/VDC, manageeritav
Tootekood: EE-100-183-976 Võrguseadmed
Välja töötatud vastavalt standardile IEC 62443-4-1 ja kooskõlas tööstusliku küberturvalisuse standardiga IEC 62443-4-2.Toetab IEEE 802.3bt PoE-d kuni 90 W väljundvõimsusega pordi kohta.Turbo Ring ja Turbo Chain (taastumisaeg < 20 ms @ 250 lülitit) , ja RSTP/STP võrgu redundantsi tagamiseks.Lai valik toiteallikaid paindlikuks kasutuselevõtuksKompaktne ja paindlik korpuse disain, mis sobib piiratud ruumidesseToetab MXstudio't lihtsaks, visualiseeritud tööstusvõrgu haldamiseksEDS-4012-seeria on 12-portiline hallatavate Fast Ethernet-kommutaatorite seeria, millel on võimalus kasutada nelja 1 Gbit/s kiudoptilist üleslüliporti. See seeria pakub ka nelja 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+) ja 802.3bt standardile vastava Ethernet PoE-portiga mudelit, et ühendada suure ribalaiusega PoE-seadmeid.Redundantsed Ethernet-tehnoloogiad, nagu Turbo Ring, Turbo Chain ja RSTP/STP, suurendavad teie süsteemi töökindlust ja parandavad võrgu magistraalvõrgu kättesaadavust. EDS-4012-seeria on loodud spetsiaalselt nõudlike rakenduste jaoks, nagu video- ja protsesside jälgimine, ITS ja DCS-süsteemid, mis kõik saavad kasu skaleeritavast magistraalvõrgustikust.EDS-4012-seeria vastab IEC 62443-4-2 ja IEC 62443-4-1 tööstusliku küberturvalisuse sertifikaatidele, mis hõlmavad nii toote turvalisuse kui ka turvalise arenduse elutsükli nõudeid, aidates meie klientidel täita tööstuslike võrkude turvalise projekteerimise nõuetele vastavust.10/100BaseT(X) Ports (RJ45 connector) EDS-4012-4GS-LV/-HV/-T models: 8EDS-4012-4GC-LV/-HV/-T models: 8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionPoE Ports (10/100BaseT(X), RJ45 connector) EDS-4012-8P-4GS-LVA/-LVB/-T models: 8100/1000BaseSFP Ports EDS-4012-4GS-LV/-HV/-T models: 4EDS-4012-8P-4GS-LVA/-VB/-T models: 4Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP) EDS-4012-4GC-LV/-HV/-T models: 4Standards IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for 1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for flow controlIEEE 802.3ad for Port Trunk with LACPIEEE 802.1Q for VLAN TaggingIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1X for authenticationIndustrial Protocols EtherNet/IPModbus TCPPROFINET IO DeviceManagement IPv4/IPv6Flow controlBack Pressure Flow ControlDHCP Server/ClientARPRARPLLDPFiber checkPort Mirroring (SPAN, RSPAN)Linkup DelaySMTPSNMP TrapSNMP InformSNMPv1/v2c/v3RMONTFTPSFTPHTTPHTTPSTelnetSyslogPrivate MIBFilter GMRPGVRPGARP802.1Q VLANIGMP Snooping v1/v2/v3IGMP QuerierRedundancy Protocols STPRSTPTurbo Ring v2Turbo ChainRing CouplingDual-HomingLink AggregationMRPMSTPSecurity Broadcast storm protectionRate LimitTrust access controlStatic Port LockMAC StickyHTTPS/SSLSSHRADIUSDHCP SnoopingTACACS+Login and Password PolicyAccess control listTime Management SNTPNTP Server/ClientNTP AuthenticationIEEE 1588v2 PTP (hardware-based)Supported power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017Protocols IPv4/IPv6TCP/IPUDPICMPARPRARPTFTPDNSNTP ClientDHCP ServerDHCP Client802.1XQoSHTTPSHTTPTelnetSMTPSNMPv1/v2c/v3RMONSyslogMIB P-BRIDGE MIBQ-BRIDGE MIBIEEE8021-SPANNING-TREE-MIBIEEE8021-PAE-MIBIEEE8023-LAG-MIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBSNMPv2-MIBRMON MIB Groups 1, 2, 3, 9MAC Table Size 16 KJumbo Frame Size 9.216 KBMax. No. of VLANs 256VLAN ID Range VID 1 to 4094IGMP Groups 512Priority Queues 4Packet Buffer Size 1 MBLED Indicators PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNCConsole Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)USB Connector USB Type A (Reserved)Alarm Contact Channels 1, Relay output with current carrying capacity of 1 A @ 24 VDCDigital Input Channels 1Digital Inputs +13 to +30 V for state 1-30 to +3 V for state 0Max. input current: 8 mAButtons Reset buttonDIP Switches Turbo Ring, Master, Coupler, ReserveConnection 2 removable 4-contact terminal block(s)Pre-installed Power Module -LV/-LV-T models: PWR-100–LV-HV/-HV-T models: PWR-105-HV-I-LVA/-LVA-T models: PWR-101-LV-BP-I-LVB/-LVB-T models: PWR-103-LV-VB-INote The EDS-4012 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.For example:EDS-4012-4GS-T + PWR-100–LV = EDS-4012-4GS-LV-TEDS-4012-4GS-T + PWR-105-HV-I = EDS-4012-4GS-HV-TIf you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4012-4GS–LV-Twith the PWR-105–HV-I, refer to the specifications of the EDS-4012–4GS-HV-T.Input Voltage -LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs-HV/-HV-T models: 110/220 VDC/VAC, Single input-LVA/-LVA-T models: 48 VDC, Redundant dual inputs-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputsOperating Voltage -LV/-LV-T models: 9.6 to 60 VDC-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC-LVA/-LVA-T models: 44 to 57 VDC (>52 VDC for PoE+ output recommended)-LVB/-LVB-T models: 12 to 57 VDC (>52 VDC for PoE+ output recommended)Input Current -LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A-LVA/-LVA-T models: 48 VDC, 5.42 A-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 APower Consumption (Max.) EDS-4012-4GS-LV/-T models: 10.52 WEDS-4012-4GS-HV-/T models: 12.22 WEDS-4012-4GC-LV/-T models: 10.7 WEDS-4012-4GC-HV/-T models: 13.35 WEDS-4012-8P-4GS-LVA/-T models:Without PoE: 13.34 WWith PoE: Max. 240 W for total PD power consumption @ 48 VDC inputEDS-4012-8P-4GS-LVB/-T models:Without PoE: 15.32 WWith PoE:Max. 180 W for total PD power consumption @ 48 VDC inputMax. 150 W for total PD power consumption @ 24 VDC input (Max. 120 W for -T model)Max. 62 W for total PD consumption @ 12 VDC inputMax. PoE Power Output per Port 90 WOverload Current Protection SupportedReverse Polarity Protection SupportedIP Rating IP40Dimensions 55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)Weight 827 g (1.82 lb)Installation DIN-rail mountingWall mounting (with optional kit)Housing MetalOperating Temperature Standard Models: -10 to 60°C (14 to 140°F)Wide Temp. Models: -40 to 75°C (-40 to 167°F)Storage Temperature (package included) -40 to 85°C (-40 to 185°F)Ambient Relative Humidity 5 to 95% (non-condensing)Industrial Cybersecurity IEC 62443-4-1IEC 62443-4-2Safety UL 61010-2-201EN 62368-1 (LVD)EMC EN 55032/35EN 61000-6-2/-6-4EMI CISPR 32, FCC Part 15B Class AEMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/mIEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kVIEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFMaritime -LV/-LV-T, PoE/PoE-T models: DNV, ABS, NK, LRVibration IEC 60068-2-6Shock IEC 60068-2-27Freefall IEC 60068-2-32Railway EN 50121-4Traffic Control NEMA TS2Power Substation IEC 61850-3IEEE 1613 Class 1Hazardous Locations -LV/-LV-T models:ATEXIECExClass I Division 2Time EDS-4012-4GC-LV/-T models: 1,036,336 hrsEDS-4012-4GC-HV/-T models: 497,392 hrsEDS-4012-4GS-LV/-T models: 874,838 hrsEDS-4012-4GS-HV/-T models: 456,870 hrsEDS-4012-8P-4GS-LVA/-T models: 799,780 hrsEDS-4012-8P-4GS-LVB/-T models: 759,924 hrsStandards Telcordia SR332Warranty Period 5 years
1
1884,80 €
1
1860,00 €
1
2019,96 €
1
1860,00 €
1
2019,96 €
Thumbnail
Võrguseade MOXA Switch Switch: 7 x 10/100BaseT(X), 3 x 10/100/1000BaseT(X) või 3 x SFP pesa, -40 kuni 75°C
Tootekood: EE-100-184-273 Võrguseadmed
3 Gigabit Ethernet ports for redundant ring or uplink solutionsTurbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancyRADIUS, TACACS+, SNMPv3, IEEE 802.1x, HTTPS, SSH, and sticky MAC address to enhance network securitySecurity features based on IEC 62443EtherNet/IP, PROFINET, and Modbus TCP protocols supported for device management and monitoringSupports MXstudio for easy, visualized industrial network managementV-ON™ ensures millisecond-level multicast data and video network recovery Introduction The EDS-510E Gigabit managed Ethernet switches are designed to meet rigorous mission-critical applications, such as factory automation, ITS, and process control. The 3 Gigabit Ethernet ports allow great flexibility to build up a Gigabit redundant Turbo Ring and a Gigabit uplink. The switches have USB interfaces for switch configuration, system file backup, and firmware upgrade, making them easier to manage. Additional Features and Benefits Command line interface (CLI) for quickly configuring major managed functions DHCP Option 82 for IP address assignment with different policies Supports EtherNet/IP, PROFINET, and Modbus TCP protocols for device management and monitoring IGMP snooping and GMRP for filtering multicast traffic Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning Configurable by web browser, Telnet/USB console, CLI, MXconfig, and ABC-02-USB automatic backup configurator QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism Port Trunking for optimum bandwidth utilization SNMPv1/v2c/v3 for different levels of network management RMON for proactive and efficient network monitoring Bandwidth management to prevent unpredictable network status Lock port function for blocking unauthorized access based on MAC address Automatic warning by exception through email and relay output
1
1473,12 €
Thumbnail
Võrguseade MOXA Switch Switch: 8 x 10/100BaseT(X) -40 kuni 75°C, PROFINET enabled
Tootekood: EE-100-184-312 Võrguseadmed
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, PROFINET enabled, -40 to 75°C operating temperature 10/100BaseT(X) Ports (RJ45 connector) 8 Auto negotiation speed Full/Half duplex mode Auto MDI/MDI-X connection Standards IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3x for flow control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1p for Class of Service IEEE 802.1Q for VLAN Tagging IEEE 802.1w for Rapid Spanning Tree Protocol Optical Fiber Optical FiberRead more
1
946,12 €
Thumbnail
Võrguseade MOXA Switch Switch: 8 x 10/100BaseT(X) 0 kuni 60°C, PROFINET enabled
Tootekood: EE-100-184-313 Võrguseadmed
Moxa juhitavatel Layer 2 kommutaatoritel on tööstusklassi töökindlus, võrgu redundants ja IEC 62443 standardil põhinevad turvaelemendid. Pakume karastatud, tööstusspetsiifilisi tooteid, millel on mitu tööstussertifikaati, näiteks standardi EN 50155 osad raudteerakenduste jaoks, IEC 61850-3 elektriautomaatikasüsteemide jaoks ja NEMA TS2 intelligentsete transpordisüsteemide jaoks.Algtaseme hallatav Ethernet-kommutaator 8 10/100BaseT(X)-portiga, PROFINET-toega, töötemperatuur 0 kuni 60 °C.Ethernet Interface10/100BaseT(X) Ports (RJ45 connector)8Auto negotiation speedFull/Half duplex modeAuto MDI/MDI-X connectionStandardsIEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3x for flow controlIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1p for Class of ServiceIEEE 802.1Q for VLAN TaggingIEEE 802.1w for Rapid Spanning Tree ProtocolOptical FiberRead moreEthernet Software FeaturesFilter802.1Q VLAN, GMRP, GVRP, IGMP v1/v2, Port-based VLANIndustrial ProtocolsEtherNet/IP, Modbus TCP, PROFINETManagementBack Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow control, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTPMIBBridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIBRedundancy ProtocolsRSTP, STP, Turbo Chain, Turbo Ring v1/v2Time ManagementNTP Server/Client, SNTPSwitch PropertiesIGMP Groups256MAC Table Size8 KMax. No. of VLANs64Packet Buffer Size1 MbitsPriority Queues4VLAN ID RangeVID 1 to 4094Serial InterfaceConsole PortRS-232 (TxD, RxD, GND), 10-pin RJ45 (115200, n, 8, 1)DIP Switch ConfigurationEthernet InterfaceTurbo Ring, Master, Coupler, ReserveInput/Output InterfaceAlarm Contact ChannelsRelay output with current carrying capacity of 1 A @ 24 VDCPower ParametersConnection1 removable 6-contact terminal block(s)Input Voltage12/24/48 VDC, Redundant dual inputsOperating Voltage9.6 to 60 VDCInput Current0.61 @ 12 VDC0.3 @ 24 VDC0.16 @ 48 VDCOverload Current ProtectionSupportedReverse Polarity ProtectionSupportedPhysical CharacteristicsHousingMetalIP RatingIP30Dimensions53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)Weight650 g (1.44 lb)InstallationDIN-rail mounting, Wall mounting (with optional kit)Environmental LimitsOperating Temperature-10 to 60°C (14 to 140°F)Storage Temperature (package included)-40 to 85°C (-40 to 185°F)Ambient Relative Humidity5 to 95% (non-condensing)Standards and CertificationsSafetyEN 60950-1, UL 508, UL 60950-1EMCEN 55032/24EMICISPR 32, FCC Part 15B Class AEMSIEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/mIEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kVIEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kVIEC 61000-4-6 CS: 10 VIEC 61000-4-8 PFMFHazardous LocationsATEX, Class I Division 2MaritimeDNVRailwayEN 50121-4Traffic ControlNEMA TS2FreefallIEC 60068-2-31ShockIEC 60068-2-27VibrationIEC 60068-2-6MTBFTime1,339,439 hrsStandardsTelcordia (Bellcore), GBWarrantyWarranty Period5 years
1
689,44 €
Thumbnail
Võrguseade MOXA antenn Tööstuslik 802.11a/b/g/n AP, -25 kuni 60°C
Tootekood: EE-100-184-358 Võrguseadmed
IEEE 802.11a/b/g/n AP/sild/kliendi tugiLihtne seadistamine ja kasutuselevõtt AeroMagigaMillisekundilise täpsusega kliendipõhine Turbo RoamingTäielik redundantsus AeroLink ProtectionigaLihtne võrgu seadistamine võrgu aadresside tõlkimise (NAT) abilIntegreeritud antenn ja toiteisolatsioon-40 kuni 75 °C lai töötemperatuurivahemik (-T mudelid)5 GHz DFS kanali tugiAWK-3131A 3-in-1 tööstuslik traadita AP/sild/klient vastab kasvavale vajadusele kiiremate andmeedastuskiiruste järele, toetades IEEE 802.11n tehnoloogiat netoandmeedastuskiirusega kuni 300 Mbps. AWK-3131A vastab tööstusstandarditele ja heakskiitmistele, mis hõlmavad töötemperatuuri, toitepinget, ülepinget, ESD ja vibratsiooni. Kaks varundavat alalisvoolu sisendit suurendavad toiteallika töökindlust ning AWK-3131A-d saab toita PoE kaudu, mis lihtsustab paigaldamist. AWK-3131A võib töötada kas 2,4 või 5 GHz sagedusalas ja on tagasiühilduv olemasolevate 802.11a/b/g paigaldistega, tagades teie traadita investeeringute tulevikukindluse. MXview võrguhaldustarkvara traadita lisand visualiseerib AWK nähtamatuid traadita ühendusi, tagades seinast seina Wi-Fi ühenduvuse.Täiustatud 802.11n tööstuslik traadita lahendus802.11a/b/g/n-ga ühilduv AP/sild/klient paindlikuks kasutuselevõtuksTarkvara on optimeeritud pika vahemaa traadita side jaoks kuni 1 km vaateväljaga ja välise suure võimsusega antenniga (saadaval ainult 5 GHz sagedusel)Toetab 60 samaaegselt ühendatud klientiDFS-kanali tugi võimaldab laiemat 5 GHz kanali valikut, et vältida olemasoleva traadita infrastruktuuri poolt tekitatud häireidTäiustatud traadita tehnoloogiaAeroMag toetab teie tööstusrakenduste põhiliste WLAN-seadete veavaba häälestamistSujuv rändlus kliendipõhise Turbo Roaminguga, mis tagab < 150 ms rändluse taastamise aja AP-de vahel (kliendi režiim)Toetab AeroLink Protectioni, et luua redundantne traadita ühendus (< 300 ms taastumisaeg) AP-de ja nende klientide vahelTööstuslik vastupidavusIntegreeritud antenn ja toiteisolatsioon, mis on kavandatud pakkuma 500 V isolatsioonikaitset väliste elektriliste häirete vastuOhtlikes kohtades traadita side Class I Div. II ja ATEX Zone 2 sertifikaatidega-40 kuni 75 °C laia töötemperatuuriga mudelid (-T) sujuva traadita side tagamiseks rasketes tingimustesTraadita võrgu haldamine MXview WirelessigaDünaamiline topoloogia vaade näitab traadita ühenduste staatust ja ühenduse muutusi ühe pilgugaVisuaalne, interaktiivne rändluse taasesitusfunktsioon klientide rändluse ajaloo vaatamiseksÜksikasjalik seadmeinfo ja jõudluse näitajate graafikud üksikute AP-de ja kliendiseadmete jaoksWLAN InterfaceWLAN Standards 802.11a/b/g/n802.11i Wireless SecurityModulation Type DSSSOFDMMIMO-OFDMFrequency Band for US (20 MHz operating channels) 2.412 to 2.462 GHz (11 channels)5.180 to 5.240 GHz (4 channels)5.260 to 5.320 GHz (4 channels) 5.500 to 5.700 GHz (11 channels) 5.745 to 5.825 GHz (5 channels)Frequency Band for EU (20 MHz operating channels) 2.412 to 2.472 GHz (13 channels)5.180 to 5.240 GHz (4 channels)5.260 to 5.320 GHz (4 channels) 5.500 to 5.700 GHz (11 channels) Frequency Band for JP (20 MHz operating channels) 2.412 to 2.484 GHz (14 channels)5.180 to 5.240 GHz (4 channels)5.260 to 5.320 GHz (4 channels) 5.500 to 5.700 GHz (11 channels) Wireless Security WEP encryption (64-bit and 128-bit)WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, TKIP, AES)WPA/WPA2-PersonalTransmission Rate 802.11b: 1 to 11 Mbps802.11a/g: 6 to 54 Mbps802.11n: 6.5 to 300 MbpsTransmitter Power for 802.11a 23±1.5 dBm @ 6 to 24 Mbps21±1.5 dBm @ 36 Mbps20±1.5 dBm @ 48 Mbps18±1.5 dBm @ 54 MbpsTransmitter Power for 802.11n (5 GHz) 23±1.5 dBm @ MCS0/8 20 MHz18±1.5 dBm @ MCS7/15 20 MHz23±1.5 dBm @ MCS0/8 40 MHz17±1.5 dBm @ MCS7/15 40 MHzTransmitter Power for 802.11b 26±1.5 dBm @ 1 Mbps26±1.5 dBm @ 2 Mbps26±1.5 dBm @ 5.5 Mbps25±1.5 dBm @ 11 MbpsTransmitter Power for 802.11g 23±1.5 dBm @ 6 to 24 Mbps21±1.5 dBm @ 36 Mbps19±1.5 dBm @ 48 Mbps18±1.5 dBm @ 54 MbpsTransmitter Power for 802.11n (2.4 GHz) 23±1.5 dBm @ MCS0/8 20 MHz18±1.5 dBm @ MCS7/15 20 MHz23±1.5 dBm @ MCS0/8 40 MHz17±1.5 dBm @ MCS7/15 40 MHzTransmitter Power Read moreReceiver Sensitivity for 802.11a (measured at 5.680 GHz) Typ. -90 @ 6 MbpsTyp. -88 @ 9 MbpsTyp. -88 @ 12 MbpsTyp. -85 @ 18 MbpsTyp. -81 @ 24 MbpsTyp. -78 @ 36 MbpsTyp. -74 @ 48 MbpsTyp. -72 @ 54 MbpsNote: Due to a limitation in the receiver sensitivity performance for channels 153 and 161, it is recommended to avoid using these channels in your critical applications.Receiver Sensitivity for 802.11n (5 GHz; measured at 5.680 GHz) Typ. -69 dBm @ MCS7 20 MHzTyp. -71 dBm @ MCS15 20 MHzTyp. -63 dBm @ MCS7 40 MHzTyp. -68 dBm @ MCS15 40 MHzNote: Due to a limitation in the receiver sensitivity performance for channels 153 and 161, it is recommended to avoid using these channels in your critical applications.Receiver Sensitivity for 802.11b (measured at 2.437 GHz) Typ. -93 dBm @ 1 MbpsTyp. -93 dBm @ 2 MbpsTyp. -93 dBm @ 5.5 MbpsTyp. -88 dBm @ 11 MbpsReceiver Sensitivity for 802.11g (measured at 2.437 GHz) Typ. -88 dBm @ 6 MbpsTyp. -86 dBm @ 9 MbpsTyp. -85 dBm @ 12 MbpsTyp. -85 dBm @ 18 MbpsTyp. -85 dBm @ 24 MbpsTyp. -82 dBm @ 36 MbpsTyp. -78 dBm @ 48 MbpsTyp. -74 dBm @ 54 MbpsReceiver Sensitivity for 802.11n (2.4 GHz; measured at 2.437 GHz) Typ. -70 dBm @ MCS7 20 MHzTyp. -69 dBm @ MCS15 20 MHzTyp. -67 dBm @ MCS7 40 MHzTyp. -67 dBm @ MCS15 40 MHzWLAN Operation Mode Access pointClientClient-RouterMasterSlaveSnifferAntenna External, 2/2 dBiOmni-directionalAntenna Connectors 2 RP-SMA femaleEthernet InterfaceStandards IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X)IEEE 802.3ab for 1000BaseT(X)IEEE 802.3at for PoEIEEE 802.1Q for VLAN TaggingIEEE 802.1X for authenticationIEEE 802.1D-2004 for Spanning Tree ProtocolIEEE 802.1w for Rapid Spanning Tree ProtocolPoE Ports (10/100/1000BaseT(X), RJ45 connector) 1Ethernet Software FeaturesManagement DHCP Server/ClientDNSHTTPIPv4LLDPProxy ARPSMTPSNMPv1/v2c/v3SyslogTCP/IPTelnetUDPVLANWireless Search UtilityMXviewMXview WirelessMXconfigRouting Port forwardingStatic RouteNATRedundancy Protocols RSTPSTPSecurity HTTPS/SSLRADIUSSSHTime Management SNTP ClientFirewallFilter ICMPMAC addressIP protocolPort-basedSerial InterfaceConsole Port RS-2328-pin RJ45LED InterfaceLED Indicators PWR1, PWR2, PoE, FAULT, STATE, SIGNAL, WLAN, LANInput/Output InterfaceDigital Inputs 2Max. input current: 8 mA+13 to +30 V for state 1+3 to -30 V for state 0Alarm Contact Channels Relay output with current carrying capacity of 1 A @ 24 VDCButtons Reset buttonPhysical CharacteristicsHousing MetalIP Rating IP30Dimensions 52.7 x 135 x 105 mm (2.08 x 5.32 x 4.13 in)Weight 860 g (1.9 lb)Installation DIN-rail mountingWall mounting (with optional kit)Power ParametersInput Current 0.6 A @ 12 VDC, 0.15 A @ 48 VDCInput Voltage 12 to 48 VDCRedundant dual inputs48 VDC Power-over-EthernetPower Connector 1 removable 10-contact terminal block(s)Power Consumption 7.2 W (max.)Reverse Polarity Protection SupportedEnvironmental LimitsOperating Temperature Standard Models: -25 to 60°C (-13 to 140°F)Wide Temp. Models: -40 to 75°C (-40 to 167°F)Storage Temperature (package included) -40 to 85°C (-40 to 185°F)Ambient Relative Humidity 5 to 95% (non-condensing)Standards and CertificationsEMC EN 61000-6-2/-6-4EMI CISPR 32, FCC Part 15B Class AEMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/mIEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kVIEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kVIEC 61000-4-6 CS: 3 VIEC 61000-4-8 PFMFHazardous Locations ATEXClass I Division 2IECExRadio EN 300 328EN 301 489-1/17EN 301 893FCC ID SLE-WAPN008MICNCCRCMSRRCWPCKCSafety EN 60950-1UL 60950-1Vibration IEC 60068-2-6MTBFTime 570,854 hrsStandards Telcordia Standard SR-332
1
815,92 €
Thumbnail
Võrguseade Fluke K-Tüüpi kaabli pikendus, 80PK-EXT
Tootekood: EE-100-157-263 Võrguseadmed
Fluke 80PK-EXT pakkumisedK-tüüpi termopaari juhtmete pikendamiseks ja parandamiseksKomplekt sisaldab 3 meetrit termopaarjuhtmeid ja 1 paari miniliitmikke (mees/naine)Maksimaalne pidev kokkupuutetemperatuur: 260°C80PK-EXT ühildub K-tüüpi termomeetritegaÜheaastane garantii
1
126,48 €
Thumbnail
Võrguseade Fluke Maandustakistuse mõõtja komplekt, 300 V, 300kΩ, CAT II
Tootekood: EE-100-175-771 Võrguseadmed
Fluke 1625-2 on ainulaadne maandusmaanduse tester, mis suudab teostada kõiki nelja tüüpi maandusmaanduse mõõtmisi:3- ja 4-pooluseline fall-of-potential (vaiade abil).4-pooluseline pinnase takistuse testimine (kasutades panuseid).valikuline testimine (kasutades 1 klambrit ja panuseid).Vaakadeta testimine (kasutades ainult 2 klambrit) Reguleeritavad piirid - kiiremaks testimiseks.IP56 klassifikatsioon välitingimustes kasutamiseksVastupidav kandekottGeneral SpecificationsMemoryInternal memory storage up to 1500 records accessible via USB portMeasuring functionInterference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DCDisplay4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibilityOperationCentral rotary switch and function keysTemperature RangeOperating temperature-10°C to 50°C (14°F to 122°F)Storage temperature-30°C to 60°C (-22°F to 140°F)Temperature coefficient±0.1% of reading/°C < 18°C > 28°CType of protectionIP56 for case, IP40 for battery door according to EN60529Max voltageWarning – socket "clamp" to socket E, ES, S or HUrms = 0 VSockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse)SafetyProtection by double and/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2Quality standardDeveloped, designed and manufactured to comply with DIN ISO 9001External field influenceComplies with DIN 43780 (8/76)Auxiliary power6 x 1.5 V alkaline (IEC LR6 or type AA)Battery life spanWith IEC LR6/type AA: typ. 3,000 measurements (RE+RH ≤ 1 kΩ)With IEC LR6/type AA: typ. 6,000 measurements (RE + RH > 10 kΩ)Dimensions (W x H x D)250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)Weight≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying caseCase materialPolyesterMeasurement of Interference Voltage DC + AC (UST)Measuring limits of error: methodFull wave rectificationMeasuring range1 V to 50 VDisplay range0.0 V to 50 VResolution0.1 VFrequency rangeDC/AC 45 Hz to 400 Hz sineAccuracy±(5% of rdg + 5 digit)Measuring sequenceApprox. 4 measurements/sInternal resistanceApprox. 1.5 MΩMax. overloadUrms = 250 VMeasurement of Interference Frequency (F)Measuring limits of error: methodMeasurement of oscillation period of the interference voltageMeasuring range6.0 Hz to 400 HzDisplay range16.0 Hz to 299.9 Hz to 999 HzResolution0.1 Hz to 1 HzRange1 V to 50 VAccuracy±(1% of rdg + 2 digit)Earthing Resistance (RE)Measuring methodCurrent and voltage measurement with probe as IEC61557-5Open circuit voltage20/48 V, ACShort circuit current250 mA ACMeasuring frequency94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R1Noise rejection120 dB (16 2/3 , 50 , 60, 400 Hz)Max. overloadUrms = 250 VElectrical Measurement SpecificationsIntrinsic Error or Influence QuantityReference Conditions or Specified Operating RangeDesignation CodeRequirements or Test in Accordance with the Relevant Parts of IEC 1557Type of TestIntrinsic errorReference conditionsAPart 5, 6.1RPositionReference position ±90°E1Part 1, 4.2RSupply voltageAt the limits stated by the manufacturerE2Part 1, 4.2, 4.3RTemperature0°C and 35°CE3Part 1, 4.2TSeries interference voltageSee 4.2 and 4.3E4Part 5, 4.2, 4.3TResistance of the probes and auxiliary earth electrodes0 to 100 x RA but ≤ 50 kΩE5Part 5, 4.3TSystem frequency99% to 101% of the nominal frequencyE7Part 5, 4.3TSystem voltage85% to 110% of the nominal voltageE8Part 5, 4.3TOperating errorB = ±(|A| + 1,15 √E21 E22 E23 E24 E25 E26 )Part 5, 4.3RB[%] = ± B/fiducial value x 100%A = intrinsic errorEn = variationsR = routine testT = type testMeasuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω0.300 kΩ to 2.999 kΩ3.00 kΩ to 29.99 kΩ30.0 kΩ to 299.9 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 Ω100 ΩAccuracy±(2% of rdg + 2 digit)Operating error±(5% of rdg + 5 digit)Measuring timeTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequenciesAdditional error because of probe-and auxiliary earth electrode resistanceRH(RS + 2000 Ω)/RE x 1.25 x 10-6% + 5 digitsMeasuring error of RH and RSTyp. 10% of RE + RS + RHMax. probe resistance≤ 1 MΩMax. auxiliary earth electrode resistance≤ 1 MΩAutomatic check if error is kept within the limits required by IEC61557-5.If after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.Automatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance RHRH with Umeas = 48 V< 300 Ω< 6 Ω< 60 Ω< 600 ΩRH with Umeas = 20 V< 250 Ω< 2.5 kΩ< 25 kΩ< 250 kΩResolution1 mΩ10 mΩ100 mΩ1 ΩSelective Measurement of the Earthing Resistance (RE Clamp)Measuring methodCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).Open circuit voltage20/48 V ACShort circuit current250 mA ACMeasuring frequency94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R1)Noise rejection120 dB (162/3, 50, 60, 400 Hz)Max. overloadMax. Urms = 250 V (measurement will not be started)Measuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω0.300 kΩ to 2.999 kΩ3.00 kΩ to 29.99 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 ΩAccuracy±(7% of rdg + 2 digit)Operating error±(10% of rdg + 5 digit)Additional error because of probe- and auxiliary earth typ. electrode resistanceRH(RS + 2000 Ω)/RETOTAL x 1.25 x 10-6% + 5 digitsMeasuring error of RH and RSTyp. of 10% of RETOTAL + RS + RHMeasuring timeTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.Minimal current in single branch to be measured0.5 mAWith transformer (1000:1)0.1 mAWith transformer (200:1)Max. interference current through transformer3 AWith transformer (1000:1)1. With recommended current clamps/transformers.Resistance Measurement (R~)Measuring methodCurrent and voltage measurementMeasuring voltage20 V AC, square pulseShort circuit current> 250 mA ACMeasuring frequency94, 105, 111, 128 Hz selected manually or automatically (AFC)Measuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω300 Ω to 2999 Ω3.00 kΩ to 29.99 kΩ30.0 kΩ to 299.9 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 Ω100 ΩAccuracy±(2% of rdg + 2 digit)Operating error±(5% of rdg + 5 digit)Measuring timeTypical 6 secondsMax. interference voltage24 V, with higher voltages measurement will not be startedMax overloadUrms max. = 250 VResistance Measurement (R DC)Measuring methodCurrent- voltage measurement as per IEC61557-4 possibleMeasuring voltage20 V DCShort circuit current250 mA DCFormation of measured valueWith 4-pole measurement wires on H, S, ES can be extended without additional error.Resistances > 1 Ω in wire E can cause additional error of 5m Ω/Ω.Measuring range0.020 Ω to 300 kΩDisplay range0.001 Ω to 2.999 Ω3.00 Ω to 29.99 Ω30.0 Ω to 299.9 Ω300 Ω to 2999 Ω3.0 kΩ to 29.99 kΩ30.0 kΩ to 299.9 kΩResolution0.001 Ω0.01 Ω0.1 Ω1 Ω10 Ω100 ΩAccuracy±(2% of rdg + 2 digit)Operating error±(5% of rdg + 5 digit)Measuring sequenceApprox. 2 measurements/sMeasuring timeTypical 4 second including reversal of polarity (2-pole or 4-pole)Maximum interference voltage≤ 3 V AC or DC, with higher voltages measurement will not be startedMaximum inductivity2 HenryMaximum overloadUrms = 250 VCompensation of Lead Resistance (RK)Compensation of lead resistance (RK) can be switched on in functions RE 3-pole, RE 4-pole (clamp), R AC, and R DC 2-poleFormation of measured valueRdisplay = Rmeasured - Rcompensated22. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.Stakeless Ground Loop Measurement (Two Clamp Stakeless)Switch positionRA 4-pole (two clamp Stakeless)Resolution0.001 Ω to 0.1 ΩMeasuring range0.02 Ω to 199.9 ΩAccuracy±(7% rdg + 3 digit)Operating error±(10% rdg + 5 digit)Measuring voltageVm = 48 V AC (primary)Measuring frequency128 HzNoise current (IEXT)Max. IEXT = 10 A (AC) (RA < 20 Ω)Max. IEXT = 2 A (AC) (RA > 20 Ω)Measuring principle: Stakeless measurement of resistance in closed loops using two current transformers.Automatic range selection.The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.
1
6725,76 €